background image

GRAND SLAM 1000  / 5 

1.  There are three (3) connection points with compression fittings on the base of each head.
2.  To identify the Port and Starboard head, note that the round steel TACO logo on the head casting 

faces outboard with the arms facing to the stern.  

3.  Use the following table for tubing connection to the manifold assembly.
4.  Using the compression fittings provided and a short piece of tubing, connect the Pump P1 fitting to 

the Manifold P1 fitting. Then connect the Pump P2 fitting to the Manifold P2 fitting.  

Note: Do not overtighten fitting, as it will distort the tubing.

5.  Connect the Manifold P1-1 and P2-1 to the “L” fitting on the Pump return. This completes the plumbing 

of the hydraulic system.

Installing the Head Assembly

1.  Connect the harness from the pump and manifold assembly to the control box. The connectors are 

color coded; the gray connector goes to the middle gray receptacle on the control box.

2.  The control panel requires a 4-1/2” x 3-3/8” opening. Pass the two (2) harnesses through the cut 

out and fasten the panel with four (4) #8 screws. Run the two (2) cables to the control box (the 

connectors are color coded Green-Green and Black-Black).

3.  Attach the main power cables to a 40-amp fuse or circuit breaker (red wire to the Positive 12V (+) and 

Black for the Negative (-)).

Electrical Installation

1.  With all the hydraulic lines attached to the head, invert the head assembly (make sure the tie wraps, 

the upper and lower mounting plates, are still in place). 

2.  Fill the reservoir with a lightweight hydraulic oil (see appendix on page 8) or ATF fluid to the level line 

on the reservoir.

3.  Note the bleed valve on one side of the “T” fitting. Attach a piece of tubing over the nipple of the 

valve and place the other end in a bottle to capture the fluid.  

Note: if using a Mighty-Vac, you can loosen the bleeder valve and vacuum the cylinder and line to 

30hg and lock the bleeder valve. For manual bleeding, attach a vinyl tube to the bleed nipple and 

the other end into a bottle to capture fluid. 

4.  Activate the power button on the control panel, select the head to be bleed (port or starboard) and 

press the up switch. Fluid should fill the line and the cylinder should raise the head. 

5.  Release the bleeder valve and push the arm back to the 0° position; this will push the air out of the 

system. Lock the bleeder valve. Using the same procedure, bleed the other head.

Bleeding The System

Содержание GRAND SLAM 1000

Страница 1: ...GRAND SLAM 1000 ELECTRO HYDRAULIC OUTRIGGER MOUNT INSTALLATION OPERATION INSTRUCTIONS TACO Marine Grand Slam Outrigger Mounts...

Страница 2: ...T JIG SAW SILICONE SEALER 8 5 16 18 STAINLESS STEEL BOLTS LENGTH BASED ON APPLICATION 7 16 1 2 9 16 OPEN END WRENCHES MIGHTY VAC BLEEDER OPTIONAL Required not included 1 GS 1000 starboard head 1 Pump...

Страница 3: ...a pie plate access cover The other option is a threaded backing plate made into the hardtop The control box and manifold must be mounted in a dry area within 2 feet of each other Installation Requirem...

Страница 4: ...ews It is most efficient to mount the pump to the left of the manifold Mount the manifold either to the right or below the pump assembly Note Port configuration P in the recommended layout 3 Route thr...

Страница 5: ...ntrol box the connectors are color coded Green Green and Black Black 3 Attach the main power cables to a 40 amp fuse or circuit breaker red wire to the Positive 12V and Black for the Negative Electric...

Страница 6: ...osition to allow operation of the Rotation Switch D This prevents unintentional rotation of the outrigger arm 3 C Port Starboard Select Switch This switch selects Lift E and Rotation D access to the s...

Страница 7: ...wn on the side you are working on Port STBD Mount When you reach the desired level position stop clicking the up down button and the outrigger will stay at that level until changed by operator LIFT UP...

Страница 8: ...8 GRAND SLAM 1000 Use a Light Hydraulic oil ISO 32 like Mobile DTE 24 of an automotive ATF Fluid Approximate capacity 1 qt Hydraulic Ports Connection Diagram APPENDIX...

Страница 9: ...GRAND SLAM 1000 9 Keypad Interface...

Страница 10: ...Bleach Clorox etc and mild abrasive cleaners Ajax Comet Soft Scrub Rubbing Compounds etc Strong cleaners 409 Engine Degreasers etc Acids of any type Such as Muriatic naval jelly or aluminum acid Alwa...

Страница 11: ...GRAND SLAM 1000 11 Need Support 1 800 653 8568 support tacomarine com tacomarine com 50 NE 179th ST Miami FL 33162 tacomarine taco_marine TACO Marine Contact Us We re here to help...

Страница 12: ...12 GRAND SLAM 1000 LEFT BLANK INTENTIONALLY...

Страница 13: ...00 percent for accurate sizing Slight scaling may still occur Therefore before drilling it is recommended that all template dimensions be measured for accuracy BOW STERN 6 00 GRAND SLAM 1000 13 GS 100...

Страница 14: ...INSTRUCT GS 1000...

Отзывы: