TAC VISTA Xenta OP Скачать руководство пользователя страница 11

R

EFERENCE

2

Introduction

3

Connection and Basic Functions

4

Dialogs with TAC Xenta 100

5

Dialogs with TAC Xenta 280/300/
401

6

Technical Data

Содержание VISTA Xenta OP

Страница 1: ...TAC Xenta OP Handbook...

Страница 2: ......

Страница 3: ...TAC Xenta OP Handbook...

Страница 4: ...ment Only licensed users of the product and the document are permitted to use the document or any information therein Distribution disclosure copying storing or use of the product the information or t...

Страница 5: ...ardware Tests 19 3 5 2 System Information 20 3 5 3 Selecting the Language of the OP Messages 20 3 5 4 Controlling the Display Light 20 3 5 5 Leaving the OP Service Menu 21 3 5 6 Selecting the OP Mode...

Страница 6: ...TAC AB July 2007 04 00065 01 en 5 3 View Acknowledge Alarms 33 5 4 Change the Time Channels 35 5 5 Access Code 37 5 6 Edit Access Code 37 5 7 Overriding Inputs Outputs 38 5 8 Daylight Saving 38 5 9 Lo...

Страница 7: ...INTRODUCTION 1 About this Manual...

Страница 8: ......

Страница 9: ...your TAC representative 1 1 Structure The manual is divided into the following parts Introduction The Introduction section contains information on how this manual is structured and how it should be us...

Страница 10: ...o possible data loss breaches of security or other more serious problems Important Alerts you to supplementary information that is essential to the completion of a task Note Alerts you to supplementar...

Страница 11: ...REFERENCE 2 Introduction 3 Connection and Basic Functions 4 Dialogs with TAC Xenta 100 5 Dialogs with TAC Xenta 280 300 401 6 Technical Data...

Страница 12: ......

Страница 13: ...is handbook has the following contents Chapter 2 In this chapter the connection of the operator panel TAC Xenta OP to the TAC Xenta 100 280 300 401 controllers is shown Chapter 3 The use of the OP tog...

Страница 14: ...The TAC Xenta OP Operator panel data sheet The handbooks for the different TAC Xenta controller units The TAC Menta User s manual Stand alone TAC Xenta 300 3000 controllers and I O modules can be com...

Страница 15: ...e lighted from beneath The light is controlled from the OP Service menu section 2 5 The operator panel is used to monitor status and to adjust setpoints and time channels It also makes it possible to...

Страница 16: ...the figure in the next section 3 3 Connecting to TAC Xenta 280 300 401 Cable between controller and Operator panel max 10 m When connecting the operator panel there are two alternatives please refer...

Страница 17: ...available from the rear if in special cases the net work configuration procedure requires this When the pin is pressed a unique hardware identity code is sent on the network Fig 3 3 TAC Xenta OP conne...

Страница 18: ...es not by itself make changes effective is used to decrease values If this button is kept depressed the stepping speed increases is used to increase values If this button is kept depressed the steppin...

Страница 19: ...mmunication mode see below The Service menu appears if both the keys and are pressed for about three seconds simultaneously OP Service menu 1 Exit service mode 2 Keyboard test 3 Display test 4 LON add...

Страница 20: ...poses 3 5 3 Selecting the Language of the OP Messages 5 National text Means that the operator can switch between different languages for those messages that are generated in the OP Select language No...

Страница 21: ...ey has been used during about 40 seconds 3 5 6 Selecting the OP Mode 10 OP mode In TAC Xenta networks the OP may working in one of two communi cation modes For communication with TAC Xenta 280 300 400...

Страница 22: ...each the Service menu and from there select the 10 Change OP mode menu The TAC Xenta 100 OP communication is described in the next chap ter Bindable is explained after the Summary below 3 6 1 Summary...

Страница 23: ...programmed via OP Service menu 4 LON address communication is here lim ited to Base units on the same channel For OP version 3 11 and earlier the following modes can be chosen OFF OP movable Two avail...

Страница 24: ...Select OP Service menu 10 OP mode and set Bindable to TAC or in OP version 3 11 OFF 2 Disconnect the OP electrically from the network 3 Remove the OP node from the data base Factory setting If the OP...

Страница 25: ...alled in an incorrect way it may be restored to the factory setting in one of two ways Reconnect the OP to the network reinstall it and perform the steps above in the correct order or Use the Nodutil...

Страница 26: ...3 Connection and Basic Functions TAC Xenta TAC Xenta OP 26 46 TAC AB July 2007 04 00065 01 en...

Страница 27: ...the LCD display In order to separate this general kind of communication from the dedi cated communication used with TAC Xenta 280 300 401 controllers the TAC Xenta OP has two different communication...

Страница 28: ...Wait for the display Xenta 100 is Configured Press DOWN to continue Press the key and wait for a display looking like Xenta 103v1 00 10 103 A v10003 units as SI NV index 000 The first two lines showi...

Страница 29: ...TAC Xenta 100 When a connection has been established see Section 4 2 Connecting to TAC Xenta 100 on page 27 a NV Network Variable index can be selected by the use of the and keys Keep the key pressed...

Страница 30: ...pressed before no change will take place The keys and will take you to the adjoining NVs in the list 4 5 Initiate Service Pin Message When the NV index selection is displayed uunits as SI NV index 00...

Страница 31: ...nta OP RU model has the capability of displaying Cyrillic characters The TAC Menta User s manual describes how you switch the character files of the OP 24 hour clock vs AM PM clock In those menus that...

Страница 32: ...e starts with the first screen showing all TAC Xenta 300 401 controllers in the network and shows how to find and change the supply air setpoint in AH02 West AH01 East AH02 West HEAT 1 North HEAT 2 So...

Страница 33: ...examples will flash When the item Alarms has been found and selected with Enter a screen like the following will appear AH02 ALARMS 6 6 P1 PUMP STOPPED 99 JAN 15 14 05 ON On the top row there is an i...

Страница 34: ...isory system like TAC Vista another indication may appear in the alarm list An asterisk in front of the signal name means that the alarm is blocked that is information about changes between alarm on a...

Страница 35: ...e shows how to change operating hours on Saturdays to be 08 00 13 30 Example Week schedule Go to the week schedule for AH02 AH02 Time schedule 1234567 08 00 12 00 MTWTF 13 00 17 00 MTWTF To get to the...

Страница 36: ...elds toggle the month value past 12 To obtain asterisks for the year value you must toggle backward from the value 94 When finished press after the last entry and then use to return to the previous me...

Страница 37: ...default codes are Medium level 1111 High level 2222 To change access level go to the following menu AH02 ACCESS CODE CODE 0000 Change code to extend menu Use to move the cursor between the digits and...

Страница 38: ...eld just in front of the displayed value A2 Fan status SF_out _0 With the cursor in the position just to the left of the 0 value use or twice to toggle up the manual override indicator Press to confir...

Страница 39: ...and to change the values When you are finished press a last time and leave the menu with If an AM PM clock is used the time is entered according to the instruc tions given in section 4 1 5 9 Log Off I...

Страница 40: ...5 Dialogs with TAC Xenta 280 300 401 TAC Xenta TAC Xenta OP 40 46 TAC AB July 2007 04 00065 01 en...

Страница 41: ...C Humidity max 90 RH non condensing Display 4 20 characters alphanumeric Mechanical Enclosure ABS PC Dimensions mm 144 96 32 Weight 0 4 kg Panel cutout mm 136 0 5 x 91 5 0 5 Enclosure rating Hand hel...

Страница 42: ...Xenta TAC Xenta OP 42 46 TAC AB July 2007 04 00065 01 en Immunity EN 50082 1 Part number Operator terminal TAC Xenta OP 0 073 0907 Operator terminal TAC Xenta OP RU 0 073 0923 Mounting kit panel TAC...

Страница 43: ...n 27 Daylight saving 38 Dimensions 41 Display 41 display 15 display network variables 13 Display backlight 20 Display Light 20 Display test 19 Docnet 9 E Enclosure rating 41 Exit service mode 21 F Fac...

Страница 44: ...5 16 Protocol 41 push buttons 15 R Reading Checking NVs 29 S screw terminals 15 16 service 27 Service menu 14 Service pin 20 service pin 17 Service Pin Message 30 Special cases 36 Standards 41 Supply...

Страница 45: ......

Страница 46: ...their respective owners Information con tained within this document is subject to changewithout no tice All rights reserved 04 00065 01 en Europe Headquarters Malm Sweden 46 40 38 68 50 Americas Dall...

Отзывы: