29
*1. The storage batteries do not charge further once full.
*2. About 1 min after power consumption decreases, stand-alone operation resumes.
*3. Output is more unstable than usual when the storage batteries have no charge.
Power Outage Occurs
Morning - Afternoon
If a power outage occurs, the inverter automatically
stops operating then starts stand-alone operation.
Remote Controller (Example)
When stand-alone operation starts, power is
supplied to the stand-alone outlets starts.
Remote Controller (Example)
The storage batteries are discharged to supplement
power shortages when there is an insufficient
amount of sunlight.
If the amount of sunlight increases, surplus solar
power is used to charge the storage batteries. *1
If power consumption exceeds power output,
stand-alone operation temporarily stops. *2
Remote Controller (Example)
If there is an insufficient amount of sunlight, power
is supplied entirely from the storage batteries. *3
Remote Controller (Example)
If the storage batteries have no charge and the
inverter is unable to supply power, the Remote
Controller shuts off.
Morning
Morning - Afternoon
Commercial Power Grid Restoration
Once there is a sufficient amount of sunlight, the
power supply can be restored.
Remote Controller (Example)
When the storage battery charge is low, power is
supplied entirely from the solar panels.
Remote Controller (Example)
Remote Controller (Example)
Remote Controller (Example)
Remote Controller (Example)
Remote Controller (Example)
Remote Controller (Example)
Once power is restored on the commercial power
grid and the inverter engages grid-tied operation,
the amount of power used during the power outage
is recharged to the storage battery.
Once the storage batteries are fully charged,
grid-tied operation starts from the set operating
mode.
Evening - Nighttime
Daytime
If power is restored on
the commercial power
grid while the Remote
Controller is out, the
Remote Controller
indicates “GRID TIED
MODE” as the
operating status.
If power is restored on the commercial power grid …
GRID ABNORMALITY DETECTED.
WILL RESTART IN 5 MIN. ONCE GRID IS
BACK TO NORMAL. PLEASE CONTACT THE
SERVICE CENTER IF THE ERROR MESSAGE
CONTINUES MORE THAN 5 MIN.