16
■
Hybrid Solar Inverter
■
Remote Controller
The indicated amount of GENERATION, CHARGE/DISCHARGE, BUY/SELL, and
CONSUMPTION are not completely accurate. Use them as a reference. (This
product is not subjected to regulations under the Weights and Measures Law.)
Displays functions of thebuttons below.
(Indications change according to the screen.)
Press the operating buttons below to execute the
desired functions.
(The display is not a touch screen panel.)
To select [ENTER], press the operating button directly
below it.
The home screen is the screen that is typically displayed while the Hybrid Solar Inverter is running.
Vents
Front Panel
Hybrid Solar Inverter
DC Switch-disconnector
Base
Display
Execute the functions that appear
on the display. (If the display goes out, pressing any
of the operating buttons to light up the display. The
home screen will appear.)
Operating Buttons
Display
Green :
Running grid-tied operation
Red :
Running stand-alone operation
Flashing red :
Automatically stopped
Lights OFF :
Grid-tied operation manually stopped
Stand-alone operation manually stopped
Grid-tied operation is on standby
Stand-alone operation is on standby
How to read LED Indicators
This button will not operate if there
is a grid outage, no solar power
available, and the battery is not
charged (drained, disconnected, or
stopped due to malfunction).
How to read RUN/STOP Button
GRID-TIED MODE : Green(SELL)
: Orange(BUY)
STAND-ALONE MODE:Green
Others : Lights OFF
RUN/STOP Button
Hybrid Solar Inverter Operating Status
GRID CONNECT
→
… Preparing to start grid-tied operation.
GRID TIED MODE
… Running normally off the grid.
MANUAL GRID STOP
… Grid-tied operation was manually stopped.
AUTOMATIC STOP
… Operation was stopped due to an error, etc.
STAND-ALONE
→
… Preparing to start stand-alone operation.
STAND-ALONE MODE
… Solar power and battery power are being supplied to the Backup Load Panel
for stand-alone operation.
STAND-ALONE STOP
… Stand-alone operation was manually stopped.
A
B
C
D
NOTE
Time/Date
Displays the current time, day, month and year.
Operating Mode
Displays the current operating
mode during grid-tied operation
(MAX POWER EXPORT Mode,
ECONOMY Mode, HOME
BACKUP Mode and PEAK CUT
Mode.)
Controlled Output Status Display
Displays the controlled output status of the inverter as a
message: “VOLTAGE REGULATION,” “TEMPERATURE
SUPPRESSION” or “TEMPERATURE . VOLTAGE
SUPPRESSION”.
A message will not appear during normal operation.
Error Code
Displays an error code if an
error occurs.
A code will not appear during
normal operation.
Operating Status
Displays the current operating
status of the inverter.
Displays the amount of solar power the
system is currently generating.
Displays the amount of power that is sold
to or purchased from the power company.
When power is sold, “SELL” is displayed
and when the power is purchased, “BUY”
is displayed.
Displays the amount of power that is
currently consumed in the home.
Displays the amount of power charged in
or discharged from the storage battery.
When the battery is fully charged,
“CHARGE” is displayed, when the battery
is discharged, “DISCHARGE” is displayed
and when the battery stops charging/
discharging, “STANDBY” is displayed.
In addition, if a fault occurs with the
storage battery, “FAULT” is displayed.
5 . 5 0
kW
GENERATION
1 . 5 0
kW
CHARGE
1 . 5 0
kW
DISCHARGE
1 . 5 0
kW
BUY
1 . 5 0
kW
SELL
1 . 5 0
kW
CONSUMPTION
– . – –
kW
STANDBY
– . – –
kW
FAULT
A
C
D
B
Names of Parts