13
Cal
The “Cal” icon flashes in the middle of the LCD display screen when
editing the length constant value in Length Mode and during calibration
testing. The Coax Clarifier™ performs a calibration and self-test pass
before starting Quality or ID testing.
If calibration fails, the “Cal” icon flashes to indicate that the unit failed
to initialize properly. Hold down the POWER button to turn the unit off or
press the test mode button again (QUALITY or ID) to proceed with testing.
battery low
The battery low icon appears when the battery is nearing depletion.
The symbol flashes when there is 30 minutes of remaining battery life
indicating the battery needs to be replaced. Results may be unreliable at
this point.
Voltage Detected Warning (Voltage!)
If voltage is detected on the cable the “Voltage!” icon flashes. A check for
voltage is performed before each test and during most tests when looping
or changing test parameters. If voltage is detected, testing stops. If the
icon appears, the Coax Clarifier™ should be immediately disconnected
from the source of the voltage.
active signal Warning (act sig)
When an active signal is detected, the “Act Sig” message flashes at the
bottom of the display screen. If an active signal is found, the unit should
be immediately disconnected from the signal source. The Coax Clarifier™
will automatically turn off after 90 seconds if the unit is not disconnected
from the active signal.