EXPLANATIONS OF CONTROLS
B1 - WELD BUTTON
Weld Cycle Start
Button is enabled when its green light is on and both clamps are down.
In Manual or Weld Only mode the green light comes on when the welder is at weld start, and remains on during a weld cycle.
In Auto mode the green light comes on when the welder is calibrated and at weld start, and remains on during the auto cycle.
B2 - ADVANCE BUTTON
Advances the welder to the next available position; Calibrates Machine in Auto mode
Button is enabled when its yellow light is on and both clamps are up.
B3 - ANNEAL BUTTON
Anneal Cycle Start/Stop; Alarm Reset
Button is enabled when its red light is on and both clamps are down.
The red light comes on at the anneal position, and remains on during an anneal cycle.
B4 - AIR BLOW-OFF BUTTON
Manually activates the air blow-off system.
P1 - ANNEAL HEAT 1 KNOB
Adjusts the anneal heat for the Ramp Stage.
Heat Range = 100 - 999
100 = 0 volts
999 = Max. Weld Voltage as set by the WELD VOLTAGE SWITCH
P2 - ANNEAL HEAT 2 KNOB
Adjusts the anneal heat for the Soak Stage.
Heat Range = 100 - 999
100 = 0 volts
999 = Max. Weld Voltage as set by the WELD VOLTAGE SWITCH
T1 - ANNEAL TIMER 1
Sets the amount of time Anneal Heat 1 is applied for the Ramp Stage.
Set the time by pressing the button below the display that corresponds with the position of the number you want to change.
T2 - ANNEAL TIMER 2
Sets the amount of time Anneal Heat 2 is applied for the Soak Stage.
Set the time by pressing the button below the display that corresponds with the position of the number you want to change.
T3 - DELAY TIME
Sets the amount of time cool down time before the air blow off activates after a blade has been welded in the auto mode.
Set the time by pressing the button below the display that corresponds with the position of the number you want to change.
S1 - WELD VOLTAGE SWITCH
Sets the maximum voltage for welding and/or annealing.
0 = Off
1 = 3.0 volts
2 = 3.6 volts
3 = 4.2 volts
4 = 4.8 volts
5 = 5.4 volts
6 = 6.0 volts
S2 - LINE VOLTAGE SWITCH
Compensates for high or low power voltage.
Select the setting that is closest to, but not below, the incoming voltage level powering the machine.