FW-200 HPA, Rev. 4
2-10
ANNEAL SETUP
SET JAW GAP
This is set at the Weld Start position and is the same setting used for welding the blade. (See WELD SETUP)
SELECT WELD VOLTAGE SETTING
Use the same setting used for welding the blade. (See WELD SETUP)
SET ANNEAL TIME 1
Type the desired Ramp Up time for the anneal cycle into ANNEAL TIMER 1.
SET ANNEAL HEAT 1
Turn the ANNEAL HEAT 1 Knob to the desired Ramp Up setting.
SET ANNEAL TIME 2
Type the desired Soak time for the anneal cycle into ANNEAL TIMER 2.
SET ANNEAL HEAT 2
Turn the ANNEAL HEAT 2 Knob to the desired Soak setting.
SET BLADE GUIDES
Adjust the BLADE GUIDES to accommodate the blade's tooth size.
ADJUST CLAMPING PRESSURE DISTRIBUTION
Check the clamping pressure distribution and adjust if necessary.
MANUAL ANNEALING PROCEDURE
1) Set the mode switch to MANUAL.
2) Setup for the desired blade size.
(See “ANNEAL SETUP”)
3) Advance to the ANNEAL position.
a) Both clamps must be UP.
b) Press the ADVANCE BUTTON until the red anneal light comes on.
4) Load a welded blade.
a) With both clamps UP, insert the blade with the weld-burr between the jaws and the teeth facing the operator.
b) Position the blade against all four guides.
c) Center the weld-burr between the jaws and clamp the blade in place.
5) Press the ANNEAL BUTTON to start the anneal cycle.
a) Both clamps must be DOWN.
6) Unclamp & remove the blade when the anneal cycle is finished.
a) The anneal cycle is finished when ANNEAL TIMER 2 reaches zero and the yellow advance light comes on.
NOTE:
The anneal cycle can be stopped early by pressing the ANNEAL BUTTON while the anneal cycle is running.