5
4
Pos. Benennung
Pumpen-Type
Art-Nr.
2
Unterschale
PSP 1500, PSP 2500
104/003645
PSP 3500, PSP 4500
104/003666
3
Griff
PSP 1500, PSP 2500
104/003646
PSP 3500, PSP 4500
104/003667
4
Rotor
PSP 1500
168/009145
PSP
2500
168/009117
5
Rotor
PSP 3500
168/009112
PSP
4500
168/009113
6
Einlaufdeckel
PSP 1500, PSP 2500
168/009146
PSP 3500, PSP 4500
168/009110
7
Zubehör
PSP 1500
104/003701
PSP
2500
104/003702
PSP 3500, PSP 4500
104/002118
BESTELLUNG BITTE SCHRIFTLICH AN FOLGENDE ADRESSE ODER WENDEN SIE SICH AN IHREN HÄNDLER!
T.I.P. - SERVICE
Siemensstraße 17 · D - 74915 Waibstadt · FAX +49 72 63 / 91 25 85 · [email protected]
Garantiebedingungen
Dieses Gerät wurde nach den modernsten Methoden hergestellt und geprüft. Der Verkäufer leistet für
einwandfreies Material und fehlerfreie Fertigung Garantie gemäß den gesetzlichen Bestimmungen des jeweiligen
Landes, in dem das Gerät gekauft wurde. Die Garantiezeit beginnt mit dem Tage des Kaufs, zu nachfolgenden
Bedingungen:
Innerhalb der Garantiezeit werden Mängel, die auf Material- oder Herstellungsfehler zurückzuführen sind,
kostenlos beseitigt. Reklamationen sind unmittelbar nach Feststellung zu melden.
Der Garantieanspruch erlischt bei Eingriff en durch den Käufer oder durch Dritte. Schäden, die durch unsachge-
mäße Behandlung oder Bedienung, durch falsches Aufstellen oder Aufbewahren, durch unsachgemäßen An-
schluss oder Installation sowie durch höhere Gewalt oder sonstige äußere Einfl üsse entstehen, fallen nicht unter
die Garantieleistungen. Verschleißteile, wie z. B. Rotor (Laufrad), Filtermaterialien und Leuchtmittel sind von der
Gewährleistung ausgenommen. Sämtliche Teile werden mit größter Sorgfalt und unter Verwendung hochwer-
tiger Materialien hergestellt und sind für lange Lebensdauer konzipiert. Der Verschleiß ist jedoch abhängig von
der Nutzungsart, der Nutzungsintensität und den Wartungsintervallen. Die Befolgung der Installations- und
Wartungshinweise in dieser Bedienungsanweisung trägt daher entscheidend zu einer hohen Lebensdauer der
Verschleißteile bei.
Wir behalten uns vor, bei Reklamationen die defekten Teile auszubessern oder zu ersetzen oder das Gerät
auszutauschen. Ausgetauschte Teile gehen in unser Eigentum über.
Schadenersatzansprüche sind ausgeschlossen, soweit sie nicht auf Vorsatz oder grober Fahrlässigkeit des
Herstellers beruhen.
Weitergehende Ansprüche bestehen aufgrund der Garantie nicht. Der Garantieanspruch ist vom Käufer durch
Vorlage der Kaufquittung nachzuweisen. Diese Garantiezusage ist in dem Land gültig, in welchem das Gerät
gekauft wurde.
Hinweise:
1. Sollte Ihr Gerät nicht mehr richtig funktionieren, so prüfen Sie bitte vorerst, ob andere Gründe, wie z.B.
unterbrochene Stromversorgung oder falsche Handhabung, die Ursache sind.
2. Beachten Sie bitte, dass Sie Ihrem defekten Gerät in jedem Fall folgende Unterlagen beifügen:
- Kaufquittung
- Beschreibung des aufgetretenen Mangels (eine möglichst genaue Fehlerangabe erleichtert uns eine
zügige Reparatur)
3. Im Falle des Reparaturbedarfs entfernen Sie bitte vor Versand in den Service, sämtliche Anbauteile die
nicht dem Originalzubehör entsprechen.
Bei Garantieanspruch, Störungen oder Ersatzteilbedarf wenden Sie sich bitte an Ihre Verkaufsstelle oder
direkt an:
T.I.P. - SERVICE
Siemensstraße 17 · D - 74915 Waibstadt · FAX +49 72 63 / 91 25 85 · [email protected]
In Österreich wenden Sie sich bitte an Ihre Verkaufsstelle oder an:
POSPISCHIL TOOLS GmbH · Elektromechanik & Elektromaschinenbau
Lützowgasse 12 -14 · A - 1140 Wien · T43 / 1 / 9 11 63 00 · Fax +43 / 1 / 9 11 63 00 - 29
Nur für EU-Länder
Werfen Sie Elektrogeräte nicht in den Hausmüll!
Gemäss Europäischer Richtlinie 2002/96/EG über Elektro- und Elektronik-Altgeräte und Umsetzung in nationales
Recht müssen verbrauchte Elektrogeräte getrennt gesammelt und einer umweltgerechten Wiederverwertung
zugeführt werden. Bei Fragen wenden Sie sich bitte an Ihr örtliches Entsorgungsunternehmen.
General safety information
Please read through these operating instructions carefully and make yourself conversant with the control
elements and the proper use of this product. We shall not be liable in the case of damage caused as a result of
the nonobservance of instructions and provisions of the present operating instructions. Any damage caused as
a result of the nonobservance of the instructions and regulations contained in the present operating instructions
shall not be covered by the warranty terms. Please keep these operating instructions in a safe place and hand
them on together with the device should you ever dispose of it.
Children and other persons not conversant with the contents of these operating instructions must not use this
device. Please keep an eye on children to make sure they will not use the unit as a toy to play with. In various
countries, applicable provisions may be in place which might contain restrictions regarding the age of the user,
and they have to be adhered to in any case.
The device must not be operated by people with restricted physical, sensory or mental capabilities unless they
are either under the supervision of a person being responsible for their safety, or receiving from such a person
instructions as how to use the device, respectively.
Please inspect the device for damage occurred during transportation. In case of damage, the retailer has to be
informed immediately, at the latest within 8 days after the date of purchase.
Please read these instructions thoroughly before using the pump!
Use:
Centrifugal pump for submersible usage with resin encapsulated motor.
The pump is suitable for use in water, e.g. for garden ponds, fountains, terraced fountains, indoor fountains, in
fi shponds, for the operation of fi lter systems, fl owing brooks etc. as well as for circulating and oxygenating
water.
The pump may not be used in or on the side of swimming pools!
Please refer to the type plate for technical specifi cations or the table on page 1.
Safety measures
-
Caution!
It may only be used in garden ponds and in their protection area if the electrical installations have
been set up to comply with the code‘s requirements. Please contact an electrician.
- Before use: Check whether mains connection and plug are intact.
- Mains voltage and type of current have to correspond to the data on the type plate.
-
The pump has to be connected to a regular safety plug socket through a residual current device
(RCD, 30 mA).
- The connection box should be located in a water-protected area. It should be at least 2 m away from the edge
of the pond
(see fi g.1)
.
- Keep the plug dry!
-
Pull out mains plug before starting to work on the pump, fountain or pond.
It is not allowed to run the pump when people are inside the water (disconnect the pump)!
-
Important!
If the mains connection or the motor housing is damaged, the pump cannot be used anymore.
It cannot be repaired since the connection is cast into the motor housing.
- Never hang up or transport the pump by the cable!
-
PSP 3500, PSP 4500 - This pump is equipped with a permanent magnet the magnetic fi elds of which
might affect cardiac pacemakers, interfere with electrical / electronical components, and delete
data from data carriers. Persons with a cardiac pacemaker are strongly advised always to keep
distance of at least 30 cm from this pump.
Start-up (see fi g. 1)
Important! Do not let the pump run dry. This could cause damage to the appliance.
- Immerse the pump completely in your pond. This causes the pump body to be fi lled with water.
- A minimum water depth of 20 cm is required for underwater operation to avoid the pump taking in air.
-
The maximum depth for submerged operation of the
2 m
pump is 2 m!
- The water temperature should not exceed 35°C.
- Do not let the pump freeze in the wintertime.
- The pump is switched on by putting the plug in the socket.
- To prevent the pump becoming unnecessarily dirty, place it above the mud in your pond, in a fi rm and
horizontal position (on a brick)!
- A range of accessories may be fi tted onto the threaded connection of the pump.
- Running in conjunction with fountain jets, the pump should be positioned fi rmly and horizontally (on a brick).
Dismantling / Assembly PSP 1500, PSP 2500 (see fi g. 2 - 5)
1. Follow the safety measures.
Disconnect the pump!
2. Push in the two brackets on the front of the pump, push the top shell (1) up and remove it.
3. Lift the entire pump (8) out of the bottom shell (2).
4. Twist the intake lid (6) clockwise by approx. 90° and pull it out of the pump (8).
5. The front bearing support (4.5) and an axial bearing washer (4.4) are situated in the inlet lid (6) or on the
axle (4.3) respectively.
GB