background image

26

 WARNING

-  To  determine  the  correct  position  one  must  ensure  that  the  radio 

signals transmitted are correctly received by the receiving unit.

-  To adjust properly room temperature, install the thermostat far from 

heat sources, airstreams or particularly cold walls (thermal bridges). 

When the remote sensor is used in conjunction with the thermostat, 

then this note is to be applied to the remote sensor itself. 

-  For remote version all wirings must be made using wires with 1,5 mm² 

minimum section and no longer than 3 m. Do not use same duct for 

signal wires and mains. 

-  Installation and electrical wirings of this appliance must be made by 

qualified technicians and in compliance with the current standards.

In the view of a constant development of their products, the manufacturer reserves the 

right for changing technical data and features without prior notice.

The consumer is guaranteed against any lack of conformity according to the European 

Directive  1999/44/EC  as  well  as  to  the  manufacturer’s  document  about  the  warranty 

policy. The full text of warranty is available on request from the seller.

ENGLISH

PORTUGUÊS

DEUTSCH

ITALIANO

FRANÇAIS

ESPAÑOL

Содержание NEW WAVE DTP Series

Страница 1: ...TERMOSTATO AMBIENTE VIA RADIO WIRELESS ROOM THERMOSTAT RADIORAUMTHERMOSTAT THERMOSTAT D AMBIANCE PAR RADIO TERMOSTATO AMBIENTE V A RADIO TERM STATO AMBIENTE VIA R DIO NEW WAVE...

Страница 2: ...2 10 10 9 8 Fig 1 Abb 1 7 4...

Страница 3: ...3 Fig 2 Abb 2 10 10 7 Fig 3 Abb 3 10 Fig 4 Abb 4 14 7 13 11 12...

Страница 4: ...selecci n sonda temperatura ambiente Jumper JP1 selec o da sonda de temperatura ambiente 1 A Sonda interna abilitata default Internal probe enabled default Innensonde aktiviert Default Sonde int rieur...

Страница 5: ...frigeraci n Jumper JP3 selec o do aquecimento arrefecimento 3 C 10 minuti default 10 minutes default 10 Minuten Default 10minutes pard faut 10minutos default 10minutos pordefeito D 3minuti 3minutes 3M...

Страница 6: ...n Test presionando 2 veces el bot n test indicado con En alternativa modi car los puentes antes de poner las bater as 4 NOTE Apr s avoir modi les ponts il est conseill de forcer une mise jour en entr...

Страница 7: ...URES Power supply 2 x 1 5V alkaline AAA type batteries Duration of the batteries 6 years at TX every 10 min 2 5 years at TX every 3 min 4 years at TX every 3 min with reduced power Measurement range 5...

Страница 8: ...e references EN 60730 1 1996 R TTE normative references ETSI EN 300 220 2 v2 1 1 OVERVIEW Thisdeviceisaradio controlledelectronicthermostattocontrolthetemperature in industrial and commercial spaces a...

Страница 9: ...rom the thermostat if the same data comes from an associated timer thermostat or if the selection is decided on the receiver using the dedicated input The receiver is able to adjust the temperature in...

Страница 10: ...ems If the thermostat is installed in close proximity to the receiver 15 metres you can also choose the 3 minute mode with reduced power The batteries will last longer when you choose the longer perio...

Страница 11: ...hat it correctly comes into connect with its spindle and then pressing it down to the bottom Red LED low battery warning The red warning LED Fig 1 on the front of the product noti es when the batterie...

Страница 12: ...front slots as shown by in Fig 1 In the Test mode the thermostat continuously transmits ON and OFF commands to the receiver with a pause of approximately 2 seconds between one and the next The LED ash...

Страница 13: ...ooth and the hole in the plastic without pressing down directly on it to make sure that it doesn t break Correctly insert the batteries respecting the correct polarity Do not use dead batteries Use al...

Страница 14: ...output relay in the receiver does not come on or off instantly The status is updated every 3 or 10 minutes See the How it works section REMEDY This is a normal operation SYMPTOM When the batteries ar...

Страница 15: ...ries are dead REMEDY Correctly insert new batteries The Installation paragraph explains how to perform the operation correctly SYMPTOM In the Test mode the LED in the thermostat ashes correctly but th...

Страница 16: ...minimum section and no longer than 3 m Do not use same duct for signal wires and mains Installation and electrical wirings of this appliance must be made by quali ed technicians and in compliance wit...

Отзывы: