14
4111-0014 — Apr. 2020
© 2020 Systems, LLC
INSTALLATION
Cantilevered Dock (for bumper projection >4”, cantilevered dock or Edge-Of-Dock leveler)
• Driveway Mount
Determine offset, then proceed with “Driveway Mount”
instructions on page 13.
• Wall Mount
Refer to the cantilever bracket table on page 39 for
available cantilever brackets and part numbers.
Anchor cantilever bracket to dock face with six (6)
wedge anchors (3/4” x 5-14” min) or weld to the
embed mounting plate with ten (10) 4” long, 1/4” fillet
welds. Where possible, cantilever bracket should also
be welded to curb angle with 1/4” fillet weld.
Note:
Walls must be poured concrete, 8” thick
minimum to install with wedge anchors. Concrete
block or brick is not acceptable.
When cantilever bracket install is complete, weld
three sides of PowerStop back plate to the cantilever
bracket with ten (10) 4” long, 1/4” fillet welds.
Offset Formula
Dim. A
Bumper Projection
Dim. B
Cantilever
-4”
= Offset
Required
4”
+ Dim. B
6”
+ Dim. B
10”
+ Dim. B
15”
+ Dim. B
Dim. A
Dim. B
Offset Required
Note:
To determine size offset required, take total
effective bumper projection (bumper size plus any
cantilever) and subtract 4”. See table and Figure 16
below.
TOLERANCES
(UNLESS OTHERWISE NOTED)
FRACTIONAL:
1/32"
DECIMAL:
.00 =
.01"
.000 =
.005"
ANGULAR:
1
DRAWN BY
CHECKED BY
DRAWING NO.
DATE
BDK
1/22/2020
S Y S T E M S
L o a d i n g D o c k E q u i p m e n t
P O W E R A M P
M C G U I R E
D L M
This print is the property of Systems, LLC and represents a proprietary article in which Systems, LLC retains any and all patent and other rights, including exclusive rights
of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture the article or articles shown therein,
such permission to be granted only by written authorization signed by an officer or other authorized agent of Systems, LLC thereof.
MATERIAL
STOCK NO.
9415-0062
FINAL ASM - PSTOP/STOPTITE 2018
REV A - ECN 18-066
Figure 16