The 

>

 button can be used to edit the Restore Time , the display changes as follows:

EDIT : Restore Monitor
Time = 05s

Errors = 000

The 

^

 and 

V

 buttons can be used to select the required Restore Time (1 to 20 seconds).

The 

YES

 button is used to confirm the selection, the 

NO

 button to abort the edit:

MENU : Restore Monitor
Time = 10s

Errors = 000

4.4.5 Codec Function

The C300xr Codec can operate in 1 of 5 selectable modes; ISDN, X.21, X.21 with ISDN
Backup - Master Unit or Slave Unit and Dial On Audio.

Dial On Audio Mode

When operating in Dial On Audio mode, the Input audio channels are monitored continuously
for activity. On detection of a signal which is above -27 dB, the unit will automatically dial the
pre-configured ISDN number for the current patch. If the ISDN call fails to be established for
any reason, the unit will re-dial until it has successfully connected through. Similarly, if the
ISDN call is terminated, other than by the unit which initiated the call, a re-dial will be
activated automatically.

Once the ISDN call has been established the Silence Timeout period is used to determine when
the call is terminated. The Silence Timeout period can be set to a minimum of 1 minute and a
maximum of 8 minutes, in increments of 1 minute.

The ISDN call can also be manually terminated by the unit which initiated the call, using the
HANG button.

NOTE: When operating in Dial On Audio Mode the VU Meters are locked to monitor the input
audio only. The user can not change the VU Meter setting to monitor the output audio.

X.21 Mode

Please note that when operating in X.21 mode, the ISDN port will still be functional, however
the audio will not be routed through to the ISDN connector.

Backup Master / Slave Mode

In the X.21 with ISDN Backup mode, the unit at one end of the X.21 line should be configured
as a Master Unit and the other unit should be configured as a Slave Unit. This prevents both
units initiating the ISDN Backup, which can cause a call conflict. ISDN Backup is initiated
following 5 seconds of loss of synchronisation on the X.21 line. The automatic X.21 Restore
occurs following 10 seconds of error free, continuous, synchronisation on the X.21 line.

NOTE: When operating in ISDN Backup Mode, it is advised that the DCE should carry X.21
termination resistors, please contact Systembase Limited or an authorised distributor for further
information.
The 

>

 button is used to select the Operating Mode for the current patch.

MENU : Codec Function

Содержание C300xr

Страница 1: ...SystemBase C300xr ISDN Audio Codec User Guide 27 April 1998 Revision 9...

Страница 2: ...l Sub Address_____________________________________ 13 4 4 2 2 5 ISDN Channel Mapping______________________________________ 13 4 4 2 2 6 ISDN Caller Line Identification CLI ___________________________...

Страница 3: ..._____________________________________ 25 7 3 Remote Trigger Port_________________________________________________ 25 8 Remote Management Ports ____________________________________________ 25 9 Physica...

Страница 4: ...s Integral ISDN Terminal Adapter 64Kbps 56Kbps 15KHz Mono Audio Over 2 x 64Kbps ISDN B Channels 7 5KHz Stereo Audio Over 2 x 64Kbps ISDN B Channels 7 5KHz Mono Audio Over 64Kbps ISDN B Channel 2 x 3 7...

Страница 5: ...Systembase C300xr 0018 013 009 Page 5 of 28 2 Front and Rear Panel Profiles...

Страница 6: ...o flash the current selection for 2 seconds Please note that if the current Patch Function is set to Dial On Audio the VU Button will be disabled since the Input audio is being monitored continuously...

Страница 7: ...he Manual Dial Option will use the Audio configurations for the currently selected patch The call status is then displayed as follows ISDN1 Ready ISDN2 Ready MUTE ISDN1 Dialling ISDN2 Ready MUTE If th...

Страница 8: ...1 of 20 A third depression of the DIAL button instructs the unit to dial the ISDN numbers associated with the selected patch The call status is then displayed as a above 3 6 HANG Button The Hang butto...

Страница 9: ...UNCTION ALARM ISDN AUDIO ISDN DEST NUMBER CH2 ISDN DEST SUB ADDRESS CH 2 ISDN LOC NUMBER CH2 ISDN LOC SUB ADDRESS CH2 ISDN AUX DATAPORT ISDN CHAN MAP CH2 CHANNEL 2 OPTIONS ISDN DATA RATE ISDN CLI CH2...

Страница 10: ...note that if the C300xr is configured in X 21 Mode the ISDN port can still function however the audio will not be routed through to the ISDN connector The Audio status is displayed on the bottom right...

Страница 11: ...next character position There is no facility to edit a character once it has been confirmed On completion of entry of up to 10 characters press the YES button to save the changes and the NO button to...

Страница 12: ...haracter position There is no facility to edit a character once it has been confirmed On completion of entry of up to 18 digits press the YES button to save the changes and the NO button to abort the...

Страница 13: ...ISDN Loc Sub Null The button is used to edit the ISDN Local Sub Address the display changes as follows EDIT ISDN Loc Sub The and V buttons can be used to scroll through A Z and 0 9 the numerical keyp...

Страница 14: ...r position There is no facility to edit a character once it has been confirmed On completion of entry of up to 18 digits press the YES button to save the changes and the NO button to abort the changes...

Страница 15: ...n or off If on is selected then the codec will automatically detect the format of the incoming audio Mono Stereo 3 7KHz 7 5KHz 15KHz 64Kbps 56Kbps and re configure its mode to match The re configurati...

Страница 16: ...o The YES button is used to confirm the selection the NO button to abort the edit MENU X 21 Audio STATUS 15KHz Stereo Please note that when operating in Mono only the Left Channel input and output are...

Страница 17: ...omatic ISDN Backup is initiated The Backup Level can be set to different values on the Master and Slave units in order to bias the sensitivity of the link in either direction The button can be used to...

Страница 18: ...is terminated The Silence Timeout period can be set to a minimum of 1 minute and a maximum of 8 minutes in increments of 1 minute The ISDN call can also be manually terminated by the unit which initi...

Страница 19: ...DIT Alarm OPTION Off The and V buttons can be used to scroll through the options OPTIONS Off Sync Loss Backup Press the YES button to save the changes and the NO button to abort the changes MENU Alarm...

Страница 20: ...rate on 1 of 10 International ISDN Standards MENU ISDN Country STATUS EURO ETSI The button is used to select the ISDN Country Standard the display changes as follows EDIT ISDN Country OPTION EURO ETSI...

Страница 21: ...l keypad can be used for entry The button confirms the character selection and moves to the next character position There is no facility to edit a character once it has been confirmed On completion of...

Страница 22: ...ion MENU Set Defaults The button is used to select the Set Defaults option the display changes as follows MENU Set Defaults Confirm Yes No Press the YES button to confirm and the NO button to abort ME...

Страница 23: ...2KHz Bandwidth 3Hz up to 3 7KHz 7 5KHz 15 2KHz Format Mono Stereo Dynamic Range 80dB I P Impedance 10K I P Level 12dBU Max I P Connectors Balanced XLR O P Impedance 100R O P Level 12dBU Max O P Connec...

Страница 24: ...ion of asynchronous data at a baud rate of 2 4Kbps Type V24 RS232 Fixed DCE Speed 2 4Kbps Async Supported Signals TXD RXD SIG_GND Connector 25 Way D Type Female When operating in 3 7KHz Stereo mode ad...

Страница 25: ...e the user can connect another straight 9 Way D Type cable from the MGR OP port of the first unit to the MGR IP port of the next unit in a Daisy Chain manner There are no limitations on the number of...

Страница 26: ...digit remote sub address blank for NULL set loc add chan 18 digit local ISDN number blank for NULL set loc sub chan 6 digit local sub address blank for NULL set cli chan 18 digit CLI number leave bla...

Страница 27: ...Level 050 Restore Time 01 MGR IP PORT Type Fixed DCE Speed 9 6Kbps Async 8 Data Bits No Parity 1 Stop Bit Signals TXD INPUT RXD OUTPUT SIGNAL GND Connector 9 Way D Type Female Table 3 MGR IP Connecto...

Страница 28: ...tead of 1KHz This is to ensure that the sample rate and the test tone signal do not beat interfere with each other Systembase Limited PO Box 3572 Warminster Wiltshire BA12 6XQ UK Tel 44 1747 861123 Fa...

Отзывы: