Warnings

The following admonitions will be presented in the different sections of the document:

Danger

• Indicates a potentially or imminently hazardous situation which, if not avoided, could result in death or

serious injury.

Warning

• Indicates a potentially hazardous situation that may result in minor or moderate injuries.

Caution

• Indicates a risk of damaging the product or prevent optimal operation.

Important

• This appliance can be used by children aged from 8 years and above and persons with reduced physical,

sensory or mental capabilities or lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and understand the hazards involved.

• Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children

without supervision.

154394 | A001

Содержание Topvex SX/C

Страница 1: ...Document in original language 154394 A001 Topvex SX C Topvex TX C Air Handling Unit Operation and Maintenance Instructions GB...

Страница 2: ...Systemair AB All rights reserved E OE Systemair AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously...

Страница 3: ...escription 4 2 2 10 Section defrosting 5 2 3 Internal components electrical connection box 6 3 Maintenance 7 3 1 Important 7 3 2 Maintenance intervals 7 3 3 Maintenance instruction 8 3 3 1 Changing su...

Страница 4: ......

Страница 5: ...ies Caution Indicates a risk of damaging the product or prevent optimal operation Important This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory...

Страница 6: ...ply air 2 Fan extract air 3 Filter supply air 4 Filter extract air 5 Heat exchanger 6 Electrical connection box 7 Damper by pass outdoor air 8 Pressure transmitter supply air fan extract air filter 9...

Страница 7: ...icing is in operation For defrosting a pressure transmitter is installed which measure the differential pressure over the heat exchanger 2 2 5 Switch module A switch module with HMI and 2 TCP IP conne...

Страница 8: ...s the night temperature indoor and outdoor temperature during 3 minutes at the set starting hour when the fans are started so that the sensors can perform a temperature measurement If above conditions...

Страница 9: ...will start After stop defrosting the unit will re start If the pressure does not decrease the air handling unit is stopped and an alarm is shown in the display Make sure that the ice is melted before...

Страница 10: ...ts 4 Terminals for internal wiring 5 Terminals for mains power supply to the unit 6 Contactor K2 On Off Pump control water HW units only not present in EL units 7 Automatic fuse 8 Automatic fuse for h...

Страница 11: ...eware of hot surface on the heating battery during maintenance and service 3 2 Maintenance intervals The table below shows recommended maintenance intervals for the unit and the installation To ensure...

Страница 12: ...an alarm in the control panel When this occurs do the following 1 Replace the filters with new ones as described below 2 Press on the alarm symbol on the control panel 3 Choose Filter alarm and press...

Страница 13: ...o be vented to maintain the batteries capacity 3 3 5 Checking the electrical heating battery After long period of time dust and pollutants can build up on the heating rods This can cause unpleasant od...

Страница 14: ...up capacitor saves the memory and keeps the clock running for at least 10 minutes after the power supply is removed Therefore if the battery replacement takes less than 10 minutes there will be no nee...

Страница 15: ...if diffusers and louvres need cleaning Check diffuser louvre openings Check if fans and exchanger block need cleaning Check if the roof unit or air intake is clogged Check ducts for visible damage an...

Страница 16: ...0V 25 A 50Hz Systemair Sverige AB Industriv gen 3 SE 73930 Skinnskatteberg Sweden 4016 W IP23 225kg Ver A Serial no 1234 567891 0001 140214 Topvex XXXX 16kW 16kW www systemair com 2 3 4 5 Fig 3 Type l...

Страница 17: ...154394 A001...

Страница 18: ......

Страница 19: ......

Страница 20: ...C Topvex TX C Operation and Maintenance Instructions 154394 en_GB 14 01 2019 A001 Systemair Sverige AB Industriv gen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 222 440 99 www syste...