background image

3

installation manual 

4.    ATTACHED FITTINGS

Please check whether the following fittings are of full scope. If there are some spare fittings, please restore them carefully.  

Fig.4-1

Never throw or beat the controller.

Before  installation,  operate  the  remote  controller  to  determine  its  location  in  a 
reception range.

Keep  the  remote  controller  at  least  1m  apart  from  the  nearest  TV  set  or  stereo 
equipment. (it is necessary to prevent image disturbances or noise interferences.)

Do not install the remote controller in a place exposed to direct sunlight or close to a 
heating source, such as a stove.

Note that the positive and negative poles are right positions when loading batteries.

This manual is subject to changes due to technological improvement without further 
notices.

Cautions on remote controller installation: 

Remote

controller

Remote controller

holder

Mounting screw B

ST2.9x10-C-H

This manual 

Four-way 
Cassette

Four-way 

Cassette (compact)

INSTALLATION FITTINGS 

Tubing & Fittings 

Remote controller & Its Frame 

Drainpipe Fittings 

Others 

SHAPE 

NAME 

3. Soundproof / insulation sheath 

6. Out-let pipe clasp 

7.Tightening band 

5. Out-let pipe sheath 

4. Out-let pipe pipe 

                                           

12. Installation manual 

13. Signal line 

8. Remote controller 

9. Frame 

10. Mounting screw 
(ST2.9×10-C-H)  

11. Alkaline dry batteries (AM4) 

1. Installation paper board         

2. Bolt  M6 

14. Connective pipe for  
restriction assembly 

15.Copper nut 

˄

Use for  pipe  

connection of engineering  
installation

˅

ON OFF

MODE

FAN

SPEED

TURBO

LED DISPLAY

TEMP

SET

TIMER

ECO

DRY E•A•H FOLLOW ME

FAN DIRECTION

SYSCONTROL RM 02

AUTO
COOL
DRY
HEAT
FAN

TIMER OFF

TIMER ON

FOLLOW ME
      TEMP

FAN SPEED

FOLLOW ME

SLEEP

MODE

Содержание SYSVRF CASSETTE MINI

Страница 1: ...SYSVRF CASSETTE MINI Cassette 600x600 VRF indoor unit INSTALLATION MANUAL GB...

Страница 2: ...use injury The appliance must be installed 2 3m above floor The appliance shall not be installed in the laundry Before obtaining access to terminals all supply circuits must be disconnected The applia...

Страница 3: ...liquid evaporating Other special conditions Carry out the specified installation work after taking into account strong winds typhoons or earthquakes Improper installation work may result in the equipm...

Страница 4: ...without further notices Cautions on remote controller installation Remote controller Remote controller holder Mounting screw B ST2 9x10 C H This manual Four way Cassette Four way Cassette compact INST...

Страница 5: ...main body from the four sides or diagonal line direction the lever indicator also can check the lever from four sides of the main body Refer to Fig 5 6 Locate the air conditioner firmly by wrenching...

Страница 6: ...i e h g n i l i e c H Horizontal indicator 45 5 3 Install The Panel Remove the air in grill Never put the panel face down on floor or against the wall or on uneven surfaces Never crash or strike it Sl...

Страница 7: ...rant oil and wrench it for 3 4rounds with hands before fasten the flare nuts Refer to Fig 6 1 Be sure to use two wrenches simultaneously when you connect or disconnect the pipes The stop valve of the...

Страница 8: ...or or soap water Cover the joint of the connecting pipe to the indoor unit with the sound proof insulating sheath fittings and bind it well with the tapes to prevent leakage Flaring Cut a pipe with a...

Страница 9: ...76cmHg Loosen and remove the square cover of stop valves A and B to open stop valve A and B completely then fasten them Disassemble the charge hose from the repair mouth of stop valve A and fasten the...

Страница 10: ...s should be incorporated in the fixed wiring according to the National wiring regulation Be sure to locate the power wiring and the signal wiring well to avoid cross disturbance and their contact with...

Страница 11: ...ng Regulation Ground the air conditioner properly to obtain a good anti interference effect CAUTION Model W 1500 5600 15 15 3 2 0 Circuit breaker fuse A Indoor unit power wiring mm2 Indoor outdoor con...

Страница 12: ...ation 1 means factory test mode 0 means add auto searching mode default setting 1 means DC fan is chosen 0 means AC fan is chosen 00 means DC fan static pressure is 0 reserved 01 means DC fan static p...

Страница 13: ...f COOLING with the remotecontroller andcheckthefollowingpointsperthe Owner s Manual If there is any malfunction please resolve it as per chapter Troubles And Causes The indoor unit Whether the switch...

Страница 14: ...SYSVRF CASSETTE MINI_IM EN April 2014 MDV11I 025EW...

Отзывы: