7
Icon
Text
Description
Central
Vacuum
Cleaner
Function sets speed of supply air fan to
High
level and extract air fan to
Low
level to increase air pressure within the apartment for better dust collection
through central vacuum cleaner.
Function can be activated via digital input —
Central Vacuum Cleaner
Function
.
Cooker Hood
Sets speed of both supply and extract air fans to
Maximum
level to increase
airflow in the cooker hood.
Function can be activated via digital input —
Cooker Hood Function
.
Configurable
Digital Input
1
Configurable digital input for custom user function. Airflow levels for both fans
are freely configurable.
High–priority function.
Configurable
Digital Input
2
Configurable digital input for custom user function. Airflow levels for both fans
are freely configurable.
Mid–priority function.
Configurable
Digital Input
3
Configurable digital input for custom user function. Airflow levels for both fans
are freely configurable.
Low–priority function.
Pressure
Guard
Configurable digital input for pressure switch connection. Airflow levels for both
fans are freely configurable.
4.5.1.3.1Configurable digital inputs
A custom airflow settings for supply and extract fans can be set and assigned to a digital input. Each fan can have a dif-
ferent airflow setting.
Configurable digital input can be activated via signal triggered by push button, presence detector or any other external
device with digital output, such as Building Management Systems (BMS)
Configurable digital inputs are grouped in levels of priority,
Configurable Digital Input 1
being the highest,
meaning it can’t be overwritten by other user functions.
4.5.1.4 Digital input and Mode hierarchy
User modes and functions have a different hierarchy. User functions activated via HMI or mobile APP, such as
AWAY
,
CROWDED
,
FIREPLACE
,
HOLIDAY
and
REFRESH
, are interrupted by manual selection of
AUTO
and
MANUAL
fan modes.
A
FIREPLACE
function has the highest priority between user functions. Other functions activated via HMI/APP can in-
terrupt each other.
If
FIREPLACE
function is hard-wired on the connection board and configured as digital input (DI) then it has a higher
priority than
AUTO
and
MANUAL
mode. Digital input for a
FIREPLACE
function has also a higher priority than other
hard-wired digital inputs (DI) for:
AWAY
,
CENTRAL VACUUM CLEANER
,
COOKER HOOD
,
CROWDED
,
HOLIDAY
or
REFRESH
.
| 01_1.8.0