Important safety information 

DVV 16.08.2021 

1.1.2 

List of instructions for action 

Instruction for action 

 

 

Carry out this action. 

 

 

(if applicable, further action) 

 

 

 

1.2 

Notes on the documentation 

 

 

WARNING 

Hazard as a result of improper dealing with the fan 

These operating instructions describe safe use of the device. 

 

Read the operating instructions carefully! The personnel dealing with the fan must read and under-
stand the operating instructions. 

 

Keep the operating instructions with the device. They must be permanently available at the place of 
use. 

2

 

Important safety information 

2.1 

Safety notes 

Designers, installers and operators are responsible for the 

proper mounting and intended use

 

Only use the fan in a proper condition. 

 

Provide generally prescribed electrical and mechanical protective devices. 

 

During mounting, commissioning, maintenance and control, secure the place of mounting against unauthorised 
access. 

 

Observe rules for safe work. Protective working gloves, protective working shoes, safety goggles, safety helmet are 
part of personal protective equipment. Depending on object, additional protective equipment may be necessary. 

 

Safety components must not be by-passed or put out of function. 

 

Keep all the warning signs and nameplates on the fan complete and readable. 

 

Regularly instruct the personnel about safety-conscious behaviour. Requirements for personnel 

 see 2.2. The ap-

pliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities. 

 

 

NOTE 

We have carried out a risk assessment for the fans. However, it can only apply to the fan itself. After in-
stallation of the fan, we recommend to carry out a risk assessment for the whole system. In this way, you 
have the guarantee that there is no risk potential from the system. Compliance with EMC Directive 
2014/30/EC only relates to these products when they have been connected directly to the customary 
power supply. 

 

2.2 

Personnel 

2.2.1 

Mounting personnel 

 

Mounting may only be carried out by trained, qualified personnel. 

 

2.2.2 

Work on the electrical equipment 

 

Work on the electrical equipment of the fan may only be done by a qualified electrician or electro technically edu-
cated person. This person must know the relevant safety rules to recognise and avoid potentially risks. 

 

Содержание DVV-XL

Страница 1: ...DVV DVVI XS XM XL XP Installation and Operating Instructions for English original version...

Страница 2: ...with Systemair also for the event of applications for protective rights Any powers of use such as copying and forwarding rights are with us An exemplary configuration has been shown on the title page...

Страница 3: ...connection 9 7 1 Residual current circuit breaker 10 7 2 Connection of thermal protection 10 8 Commissioning 10 8 1 Preconditions 10 8 2 Safety elements 11 8 3 Commissioning 11 9 Operation 11 9 1 Safe...

Страница 4: ...f injurie from rotating parts if not covered with protective grid This warning identifies situations with a danger for life from touching impeller Failure to comply with this warning leads to the risk...

Страница 5: ...sonal protective equipment Depending on object additional protective equipment may be necessary Safety components must not be by passed or put out of function Keep all the warning signs and nameplates...

Страница 6: ...uilding structure and equipment against excessive temperatures and decrease fire escalation to the surrounding areas Snow load classification SL 0 suitable for installation only on the top of heated b...

Страница 7: ...vets screws or covering caps WARNING Electrical hazard from damaged connection cable or connections Do not use the connection cable service switch or impeller for transport or hoisting WARNING Hazard...

Страница 8: ...on request recommended factory mounted as DVVI fan DVV DVVI fans can be also equipped with accessory FSL factory mounted recommended 5 1 Technical data Size DVV XS XM XL XP Max synchron RPM at 50 or...

Страница 9: ...casing at installation The fans shall be fixed to the base with 4 screws in the corners Ensure unobstructed and uniform intake into the fan as well as free outlet Install connecting ducts and accesso...

Страница 10: ...cal expert disconnect from the power supply all pole prevent switching on again test absence of voltage earthing and short circuiting protect adjacent live parts by covers and barriers and fit a suita...

Страница 11: ...ing by trained and instructed qualified personnel only Switch the ventilator on as planned WARNING Hazard from bursting parts When checking the direction of rotation wear safety goggles Check the dire...

Страница 12: ...rly important if the supply cable is long but also to reduce the motor noise Filters may only be aban doned if proven that the voltage peaks on the connection terminals of the fan are inside stress ca...

Страница 13: ...maintenance troubleshooting cleaning and service Observe 5 safety rules for the electrical expert disconnect from the power supply all pole prevent switching on again test absence of voltage earthing...

Страница 14: ...The actual pressure drop of the system is higher than supposed the fan could operate in an unsta ble area of the fan curve Check operating point and system design Consult cus tomer service of the man...

Страница 15: ...tem from control panel as well as signal lights Test of hatch opening closing Check the joints of actuator and hatch cover are properly fastened Check if smoothly opens closes Check the safety measure...

Страница 16: ...ng Dismount carefully WARNING Hazard from falling parts When selecting the hoisting device observe the weight weight information on the name plate Carefully disconnect all wires Remove the fan from du...

Страница 17: ...DVV 16 08 2021 17 Appendix 1 Dimensions...

Страница 18: ...18 DVV 16 08 2021 Appendix 2 Installation examples...

Страница 19: ...rn the cooling ducts towards each other 2 Mount the fan on the horizontal base base pitch 10 mm m 3 Don t fix the cable on the casing 4 Enable free cooling air inlet and free outlet DVV F400 shown App...

Страница 20: ...eq con operation marking EMC See IMO Chapter 7 Prewired in D inside fan P2 18 5 kW All wires led out to service switch to connect in D on site P2 22 kW 95492 DVV 1000D4 XM F400 IE2 EMC 95448 DVV 1000D...

Страница 21: ...ply d max 10 mmq D max 18 mm 2 M16x1 5 PTC d max 1 5 mmq D max 10 mm 3 M32x1 5 M40x1 5 1 2 3 1 2 3 1 2 3 DVV 800D4 XS 4 6 XS DVV 800D6 8 XL DVV 1000D6 XL 6 XP DVV 1000D6 8 XL 6 12 XL DVV 800D4 XL 4 6...

Страница 22: ...hinery Electrical equipment of machines Part 1 General requirements EN 12101 3 Smoke and heat control systems part 3 Specification for powered smoke and heat exhaust ven tilators complies with the pro...

Страница 23: ...o prevent hazard zones being reached by upper and lower limbs EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements Note1 Compliance with EC Machinery Directive a...

Страница 24: ...achinery Electrical equipment of machines Part 1 General requirements EN 12101 3 Smoke and heat control systems part 3 Specification for powered smoke and heat exhaust ven tilators complies with the p...

Страница 25: ...istances to prevent hazard zones being reached by upper and lower limbs EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements Note1 Compliance with Supply of Mach...

Отзывы: