THREE-YEAR LIMITED WARRANTY

System Sensor warrants its enclosed smoke detector to be free from defects in
materials and workmanship under normal use and service for a period of three
years from date of manufacture. System Sensor makes no other express
warranty for this smoke detector.

No agent, representative, dealer, or employee of the Company has the
authority to increase or alter the obligations or limitations of this Warranty.
The Company’s obligation of this Warranty shall be limited to the repair or
replacement of any part of the smoke detector which is found to be defective
in materials or workmanship under normal use and service during the three
year period commencing with the date of manufacture.

After phoning System Sensor’s toll free number 800- SENSOR2 (736- 7672)
for a Return Authorization number, send defective units postage prepaid to:
Honeywell, 12220 Rojas Drive, Suite 700, El Paso TX 79936, USA. Please
include a note describing the malfunction and suspected cause of failure. The
Company shall not be obligated to repair or replace units which are found to
be defective because of damage, unreasonable use, modifications, or
alterations occurring after the date of manufacture. In no case shall the
Company be liable for any consequential or incidental damages for breach of
this or any other Warranty, expressed or implied whatsoever, even if the loss
or damage is caused by the Company’s negligence or fault. Some states do not
allow the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you. This Warranty gives
you specific legal rights, and you may also have other rights which vary from
state to state.

16

E56-6965-000

©2020 System Sensor. 10/28/2020

System Sensor® is a registered trademark of Honeywell International Inc.

Содержание OSI-RIE Series

Страница 1: ...ailable from System Sensor All proper health and safety precautions must be taken during the installation commissioning and maintenance of the product The system should not be connected to a power sou...

Страница 2: ...any provision outlined above is found to be invalid or unenforceable by a court of law such invalidity or unenforceability will not affect the remainder which will continue in full force and effect Al...

Страница 3: ...o section Humidity 0 to 95 RH Non condensing Mechanical Value Shipping Weight Complete unit 3 91 lbs 1 77kg Shipping Size 10 7 8 X 8 7 8 X 7 26 28 cm x 21 2 cm x17 78 cm Mounting Wall only without opt...

Страница 4: ...4 E56 6965 000 Dimensions Figure 3 1 Detector dimensions...

Страница 5: ...5 E56 6965 000 140 mm Figure 3 2 Reflector dimensions...

Страница 6: ...he conditions above can be addressed or minimized Some examples of applications for beam detectors might include aircraft hangars cold storage warehouses shipping warehouses enclosed parking facilitie...

Страница 7: ...sidewall may be used as a guide See Figure 3 3 The beam detector can be mounted with the transmitter receiver on one wall and the reflector on the opposite wall or both suspended from the ceiling or a...

Страница 8: ...uisance alarm or trouble conditions Initial selection of a proper mounting surface will eliminate false alarms and nuisance trouble signals Mount the detector on a stable mounting surface such as bric...

Страница 9: ...jects such as ductwork or windows should be a minimum 2 out of the center of the beam path of the beam In cases where reflective objects cannot be avoided the complete reflector blockage test can be u...

Страница 10: ...hen using one of the optional remote test stations Figure 3 16 shows the remote outputs for trouble and alarm Warning Disable the zone or system before applying power to the beam detector to prevent u...

Страница 11: ...to confirm that there are no obstructions or reflective objects within 15 38 1cm of the beam s path Insert the OSP 002 in the slot provided in the eyeball at 06 00 and move the eyeball The eyeball mo...

Страница 12: ...oing maintenance to prevent unwanted alarms Before testing the detector check for the presence of the flashing green OK LED at the receiver making sure not to disturb or block the beam If it does not...

Страница 13: ...nce Congratulations You have completed the final installation and alignment procedure Operation After A Power Failure The detector has the reflector location position set sensitivity and other commiss...

Страница 14: ...Station l Blinks till reset from FACP Trouble Drift Compensation Off 3 Quick Blinks Blink Long Term Drift Reference Out of 20 Range l Reduced IR Signal l Clean detector and reflector Trouble Beam Bloc...

Страница 15: ...uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that...

Страница 16: ...tion number send defective units postage prepaid to Honeywell 12220 Rojas Drive Suite 700 El Paso TX 79936 USA Please include a note describing the malfunction and suspected cause of failure The Compa...

Отзывы: