FURTHER PIPEIQ™ CAPABILITIES
Creating a Project

To create a project select 

New

 from the 

File

 menu or click on the 

toolbar . 
The 

New Project

 dialog box appears .

In the 

File Name

 box, type the name of the project, and then click 

Save

 . 

The PipeIQ™ project file is created.
A project can comprise a site, buildings, floors, and devices. When 

creating a project, these items are created by default; they must 

be  defined  before  designing  the  pipe  layout.  For  information  on 

configuring  elements  on  a  site,  see  the  PipeIQ™  Help  (select 

PipeIQ™ Help

 from the

 Help

 menu . 

Note:

  It  is  possible  to  add  new  buildings,  floors  and  devices  to 

a project after the initial site configuration is complete. Editing or 

modifying a project is carried out in the 

Configuration

 mode; for 

more information on adding elements to a project, refer to the 

PipeIQ™ Help Menu .

Designing a Pipe Layout

To create an effective layout, the designer must have knowledge 

of the following:
Local codes and standards for the site
Pipe network design
Creating layouts using drawing packages (e .g . AutoCAD

®

 software) 

and similar tools producing DXF format files.

For more information on using the Pipe Design Application Tools, 

see the PipeIQ™ Help Menu .

Creating Reports

PipeIQ™ can generate the following reports . 

Configuration Reports

Event Log Report
Pipe Layout
Bill of Materials .
For more information on using the Report options, see the PipeIQ™ 

Help Menu .

PipeIQ™ Help

The online help is a guide through the PipeIQ™ application . The 

Help opens in a separate window where it is possible to search and 

navigate to information on different topics .
Select 

PipeIQ™ Help

 from the 

Help

 menu or press 

F1

 . When you 

press 

F1

 the help topic for the active window is invoked . 

Using Help - Navigation Pane (Left Pane)

This pane includes 

Contents

Search

 and 

Index

 tabs . Click on the 

tab to access the content of each .

Index:

 This tab contains a multilevel list of keywords and keyword 

phrases . To open a topic in the 

Display

 pane (Right pane) associated 

with a keyword, double click the keyword . If the keyword is used in 

more than one topic, a dialog box is displayed so you can select 

the topic to view, and then click 

Display

 or double-click the topic.

Search:

 This tab helps you to search for a topic or content . Type 

the word to search and press 

Enter

 on the keyboard . The list of 

topics is displayed below . Double click the topic to show it in the 

Display

 pane . 

Contents:

 This tab lists the Table of Contents that contains 

categorized books and pages . When you double click a closed 

book it opens to display its topics, and when you click an open 

book it closes . Double click a topic to show it in the 

Display

 pane .

Using Help - Display Pane (Right Pane)

The 

Display

 pane on the right of the online help displays the 

content for the selected topic .

Blue Underlined Text

 Indicates a link to a different topic . 

Green Italicized Text

 Indicates a link to more information or 

images in the same topic. Re-click the link to hide the information 

or image .

Содержание FAAST LT

Страница 1: ...control parameters from a PC running the proprietary software application PipeIQ Version 2 3 and above This manual describes how to monitor and configure the various operating parameters available in...

Страница 2: ...ice is in Normal the Service Mode state is entered automatically when the front cover is opened The FAAST LT unit switches off the power to the unit Once the service action is complete and the front c...

Страница 3: ...purposes only Manually setting the fan speed to change the air flow will not alter the associated hi lo flow limit settings in the FAAST LT unit Therefore this option should not be used to set or cha...

Страница 4: ...el 6 0 50 obs ft 1 64 obs m Level 7 1 00 obs ft 3 28 obs m Level 8 1 50 obs ft 4 92 obs m Level 9 2 00 obs ft 6 56 obs m To set these levels ensure the Configuration tab is selected in the left pane a...

Страница 5: ...ions see the PipeIQ Help Menu PipeIQ Help The online help is a guide through the PipeIQ application The Help opens in a separate window where it is possible to search and navigate to information on di...

Страница 6: ...r 2 enabled YES NO 8 Daylight saving enabled YES NO AUTO Allows the real time clock date to change for a daylight saving period 1 hour NO Daylight saving off YES period is specified by parameters 9 an...

Страница 7: ...t sets the fan speed to reach the reference flow programmed in the device In Manual mode the user can set the fan speed Use PipeIQ LT to change default configuration of the reference flow both modes a...

Страница 8: ...ated by external input Note that only one action can be selected at a time Note External input only active in NORMAL state 50 External input silences sounders YES NO 51 External input resets device YE...

Страница 9: ...ethod used to indicate an alarm SENSOR MODE When remote output on a sensor is set ON for configured time that sensor channel goes into alarm When the remote output turns OFF the channel stops signalli...

Страница 10: ...YES 19 Channel 2 alarm is latched YES NO YES YES YES 20 Alarm delay 0 240 s 0 0 0 21 Auxiliary relay is used for channel 2 faults YES NO YES YES YES 22 Channel 1 label 16 char ASCII code from 32 to 12...

Страница 11: ...MI 17 00 17 00 17 00 60 Holiday day 1 date DD MM empty empty empty DD MM empty empty empty 79 Holiday day 20 date DD MM empty empty empty 80 Sounder activation mode On Pre alarm On Alarm Alarm Alarm A...

Страница 12: ...32 to 127 X X 2 24 Channel 1 fan speed mode Manual Auto Auto Auto Auto 25 Channel 2 fan speed mode Manual Auto X X Auto 26 Channel 1 manual fan speed 0 10 X X X 27 Channel 2 manual fan speed 0 10 X X...

Страница 13: ...Sounder activation mode On Pre alarm On Alarm X X X 81 Day night mode enabled YES NO X X X 82 Monday is holiday YES NO X X X 83 Tuesday is holiday YES NO X X X 84 Wednesday is holiday YES NO X X X 85...

Страница 14: ...t X X User can configure a specific delay between fault condition and fault indication 0 240 s Fault F013 HIGH FLOW FAULT CH1 Channel 1 flow is over the configured limit X X User can configure a speci...

Страница 15: ...feet X Please clean the sensor Alert A009 COMPENSATION 0 6 DIRTY ALERT S1 The sensor 1 chamber is very dirty 0 6 feet X Please clean the sensor Alert A010 DRIFT LIMIT ALERT S1 The sensor 1 chamber is...

Страница 16: ...2 2 2 3 2 4 2 5 2 6 2 5 2 5 7 8 9 2 5 10 2 5 FAN SPEED 10 2 5 11 12 13 2 5 14 3 15 3 16 3 17 3 5 18 3 5 3 5 END 4 4 Example Pipe Configuration 1 Channel Single Pipe 100m x 18 Holes Class C Hole 2 Hol...

Страница 17: ...ing 5 10 10 10 10 10 10 5 4 8 75m 0 2 75m HOLE SIZE mm 1 2 5 2 2 5 3 2 5 4 3 5 3 6 3 7 3 8 3 9 3 10 3 11 12 13 14 15 16 17 18 END END HOLE Typical Example Pipe Configuration 1 Channel T Piece 2 Pipes...

Страница 18: ...Configuration 1 Channel Single Pipe With Filter Class C FILTER HOLE SIZE mm 1 3 5 2 4 3 3 4 3 5 3 5 END 3 5 Hole 4 Hole 3 Hole 2 Hole 1 5 3 5 6 7 3 5 6 Hole 6 6 6 6 6 Hole 7 6 6 End hole FAN SPEED 6 3...

Страница 19: ...D200 100 00 19 I56 3888 005 System Sensor Europe Pittway Tecnologica S r l Via Caboto 19 3 34147 TRIESTE Italy http www systemsensoreurope com...

Отзывы: