3.4
Specification
General
Functions
•
Real time pressure transient monitoring
•
Burst event data (in conjunction with Flow meter)
•
Pressure & flow delivery (when used with customer supplied flow
meter)
Interface
•
Remote managed alerts (SMS, Email)
SIM Card
•
Standard size with GPRS allowance
Cellular
•
3G/GPRS
Sample rates
•
Pressure 128S/s
•
Summary data 1 s/min or 1 s/15 min
•
Flow 1 S/s
Pressure Range
•
0-20 Bar absolute
Pressure accuracy
•
0.25%
Temperature Range
•
-20°C to +65°C (See Frost Protection Chap 3.5)
Flow Meter inputs
•
Pulse Input 1: Internal pull up, Pulses or Forward Pulses.
•
Pulse Input 2: Internal pull up, Direction or Reverse Pulses.
•
Alarm Input: Internal pull up, Alarm Signal
Flow Meter Input Voltage
•
Inputs internally pulled up to 3.3V, compatible with open
collector or relay switched outputs.
•
Low voltage must be less than 0.5V with respect to ground
Control Unit: Part no. 100808
Enclosure
•
Housing: Acetal
Dimensions
•
108mm x 108mm x 49mm (4.2” x 4.2” x 1.9”)
Weight
•
0.95Kg (2lb 1 0z)
Environmental rating
•
IP68
Antenna
•
External 3G/GPRS (various options available)
•
Internal GPS
*12V 19AHr Rechargeable Battery: Part no. 101667
Type
•
Rechargeable Lithium iron phosphate
Voltage
•
12 V
Enclosure
•
Housing: ABS
Environmental rating
•
IP68
Dimensions
•
205mm x 89.5mm x 115mm
Weight
•
3Kg
Table 2: PIPEMINDER-S Specification