To delete a recording file, check the corresponding checkbox in
Figure
3-8
and click the ‘
Delete
’ button. After deletion, the checkbox in the
Select
column will turn
grey and the recording file become unplayable and undownloadable.
Check All
means to select
all available items in the current page;
Uncheck All
means to cancel all selections in the current
page;
Inverse
means to uncheck the selected items and check the unselected.
3.3.2 Recording Parameters
Figure 3-10 Recording Parameter Configuration Interface
See Figure 3-10 for recording parameter configuration. Users can configure the parameters
depending on actual requirements. The table below explains the items in Figure 3-10.
Item
Description
Select Channel
Select the current channel to be configured.
Recording Start
Condition
There are five options available: Voltage, Barge-in, DTMF, Always Recording and
Voltage (after call connection).
Recording Start
Condition
Description
Voltage
Start recording once pickup operation is detected.
Barge in
Start recording once Barge-in is detected.
DTMF
Start recording once valid DTMF key combination is detected.
Always recording
Never stop recording since the recording service starts.
Voltage (after call
connection)
To select this option, you have to enable the polarity reversal
feature first. If this option is selected, the recording will not start
until the called party picks up the call, and it only contains the
data of conversation, excluding the dialing tone.
Note:
When the “Always recording” mode is selected, the recording management
software will by default generate a recording file at the end of each 50-minute
recording. Before each recording file is formally generated, it can be found neither
in the Recording Inquiry interface nor under the Record directory in FTP, but its
temporary file can be found under the temp directory in FTP.
DTMF Key
Combination
This item is valid only when the
Recording Start Condition
is set to
DTMF
. The
system will start recording once the DTMF key combination are pressed in the right
order.
Minimum Recording
Length
Only when the recording time exceeds the set value of this parameter will the
recording be saved into a file. Range of value: 1~60s.
Compression
Format
The compression format of the recording files. Currently G.711
μ
, G.711, ADPCM
and G729A are supported.
File Format
The save format of the recording files. Currently only wav and vox are supported
ATP2410 User Manual (Version 4.0.0.0)
Page 15