background image

 
 
 

 

SAFETY INSTRUCTIONS 

 
The purpose of safety symbols is to attract your attention to possible danger. Safety symbols, and their 
explanations, deserve careful attention and understanding. The Safety warnings do not by themselves 
eliminate  any  danger.  The  instructions  or  warnings  they  give  are  not  substitutes  for  proper  safety 
procedures.  
 
SYMBOL 

MEANING 

   

Safety Alert Symbol: Indicates DANGER, WARNING,OR CAUTION. 
Attention is required in order to avoid serious personal injury. This symbol may also be 
used in conjunction with other symbols or pictographs. 

NOTE 

Notes advise you of information or instructions vital to the operation or maintenance of the 
Equipment. 

 

 

 

IMPORTANT SAFETY INFORMATION 

 

READ ALL INSTRUCTIONS BEFORE OPERATING 
 

  Upon  receipt,  unpack  and  inspect  the  unit  for  damges  that  may  have  occurred  during 

shipment.  If  damage  is  found,  contact  the  shipping  carrier  and  Syntron  Material  Handling 
immediately. 

  Read instructions carefully. Be familiar with the controls and proper use of the unit. 

  Do not operate the unit when Tired, ill, or under the influence of alcohol, drugs or medication. 

 

Product safety labels must remain highly visible on the equipment. Establish a regular schedule to check 
visibility. If you need to replace safety labels, contact Syntron Material Handling for an additional supply 
free of charge. 
 
The instructions and data in this manual are vital to the proper installation and operation of this equipment. 
In order to avoid delays due to faulty installation and operation of this equipment. In order to avoid faulty 
installation  and  operation,  please  see  that  these  instructions  are  read  by  the  persons  who  will  install, 
operate and maintain this equipment. 
 
NOTE:  Supporting  information,  such  as  drawings,  may  be  attached  to  the  manual.  The  information 
contained therein takes precedence over corresponding information printed in this manual. 

  

Содержание BF-4-ALF

Страница 1: ......

Страница 2: ...1 Service Manual Syntron Electromagnetic Feeder Models BF 4 ALF and BF 4 ASLF stainless steel hardware Installation Operation Maintenance...

Страница 3: ...ge 4 Theory of Operation 4 Installation 5 Installing the Control 6 Operation 7 Maintenance 7 Spring Replacement 8 Magnet Replacement 8 Air Gap Adjustment 9 Measuring the Stroke 11 Troubleshooting 12 O...

Страница 4: ...is found contact the shipping carrier and Syntron Material Handling immediately Read instructions carefully Be familiar with the controls and proper use of the unit Do not operate the unit when Tired...

Страница 5: ...ransfer point as possible minimizing product drop INSPECTION AND STORAGE WARNING Do not drop the control or feeder the force of the impact may damage the coponents Upon receipt carefully unpack and in...

Страница 6: ...sing the pulsating action described above the trough assembly moves particles being conveyed forward the pulls back and allows them to land downstream Repeating this action at 1800 cycles per minute 6...

Страница 7: ...ure 4 CAUTION The feeder must not come in contact with any rigid object or adjacent surface that could hamper its vibrating action Any connections such as dust seals between the trough and adjacent ob...

Страница 8: ...eration the feeder performs with a smooth even stroke If a loud striking noise occurs immediately turn off the unit and verify that the feeder drive and or trough are not contacting any adjacent objec...

Страница 9: ...d clamp Remove the bolts that secure the leaf springs to the base and the bolts that hold the springs to the trough mounting bracket Install the new spring assembly in the reverse order to which the o...

Страница 10: ...will be necessary Adjusting the air gap is a very delicate procedure and may require operation time to obtain the proper setting The air gap is correct when the armature and magnet faces are as close...

Страница 11: ...e that all the magnet screws are secure B Check to make sure that the longitudinal pan ribs are not contacting the base casting To close tighten the air gap 1 Loosen the upper socket head adjustment s...

Страница 12: ...etal stroke gauge attached to the side of the trough rib Refer to Figure 6 While the feeder is operating the inner lines of the gauge appear as an X and the stroke should be read at the intersection o...

Страница 13: ...voltage is below voltage indicated on nameplate Increase line voltage as designated on the nameplate Unit in contact with rigid object Isolate the unit Spring action may be hampered Remove and clean...

Страница 14: ...epair Open winding on rheostat Replace Replace only with parts recommended or supplied by SMH NOTE Some items are equipped with removeable options such as screen panels or covers these items must be i...

Страница 15: ...14...

Страница 16: ...07 Flat Washer 5 8 Zn Pl 2 H0117501 Flat Washer 5 8 SS ONLY H0117502 Belleville Washer 5 8 2 0013X115 Belleville Washer 5 8 SS ONLY 0013X131 K Hex Socket Hd Cap Screw 3 8 24 x 1 3 4 Full Thread 1 H045...

Страница 17: ...Z Pl 4 H0113609 Lockwasher 1 2 SS Only H0113610 Plainwasher 1 2 Z Pl 4 H0117301 Plainwasher 1 2 SS Only H0117202 AB Ground Strap 1 6510 014 D AC Drive Screws 2 H0457102 Do not remove or paint over sa...

Страница 18: ...ctory Order Number 3 Quantity of parts required 4 Syntron part number from manual 5 Description of part 6 Shipping instructions Syntron Material Handling reserves the right to alter at any time withou...

Страница 19: ...Hwy 145 South Saltillo Mississippi 38866 Phone 662 869 5711 Fax 662 869 7493 Toll Free 800 356 4898 info syntronmh com Changshu 2 Road No 1 Changshu Export Processing Zone Changshu Jiangsu China 21551...

Отзывы: