SYNTHESIS TECHNOLOGY
PAGE
11
MOTM-650 USER’S GUIDE
WWW.SYNTHTECH.COM
Off
With inversion
Off
, the keyboard plays normally.
On
When inversion is
On,
the note numbers are reversed, so that Note #0 becomes #127, #1
becomes #126, etc. This is useful for playing your keyboard backwards like Joe Zawinul.
Backlght
Auto
The
Backlight
setting controls the output level of the
LCD
’s backlight. It can be set to
Off
,
Dim
,
Normal
,
Bright
, and
Auto
.
Auto
will turn the backlight on whenever a button is
pressed, leave it on as long as the setting is being changed, then turn it off a few seconds
the last button is released.
Status
Show=
On
The
System Status
setting turns the display of status updates
On
or
Off
.
On
When system status is
On,
status updates are shown whenever the LCD is idle for a few
seconds. The status update shows the current MIDI channel and voice allocation mode
setting for each voice group. If more than one voice group is enabled, then the updates
rotate through each voice group’s status every few seconds.
Off
With system status is
Off
, no status updates are shown.
SysexDev
ID=Globl
The
SysEx Device ID
setting selects the device ID used in system exclusive messages.
ID=Globl
When the ID is set to
Global
, the 650 will process all valid SysEx messages it receives. It
will also transmit messages using the Global ID, which will be processed by any other 650s
that receive them.