CIPHER 1022 User Manual
- 17 -
d. Upon receipt of an invalid value, CIPHER 1022 will
activate a "L-L-L" beep for warning. For example,
trying to set a minimum/maximum data length larger
than 40.
e. If the second label is not a value label, CIPHER 1022
will drop the first label as if it is never scanned. For
example, scan "INTER-CHARACTER DELAY" and
then scan "CODE 39 ENABLE" will enable the
CODE 39 reading whereas leave the inter-character
delay settings unchanged.
3. Modification of the prefix / postfix settings
a. Read Prefix Start (Postfix Start) label. CIPHER 1022
will echo a short beep.
b. Read HEXADECIMAL LABELS. Each prefix (postfix)
character is composed of 2 hexadecimal labels.
Please reference ASCII Table / Kbd Wedge Map
Table for correct assignment. CIPHER 1022 will echo
a short beep when scanning hexadecimal labels.
c. Read Prefix End (Postfix End) label to complete
setting. CIPHER 1022 will echo a L-H beep.
9.5 Exit From Configuration Mode
There are 2 ways to leave configuration mode,
•
Reading the "ABABDON" label : This will leave all settings
unchanged, and CIPHER 1022 will exit from the
configuration mode.
•
Reading the "UPDATE" label : This will update all the
changes made during configuring, and CIPHER 1022 will
exit from configuration mode.
CIPHER 1022 will activate a L-H-L-H-L-H beep and restart
normal operation when leaving configuration mode.