63
No Brew Pressure,
Pump Motor is Not
Running
●
Check that the pump reset button on the face of the control box (white
button with “10” on it) is not tripped (popped out).
●
Check the pump switch in the group top to make sure it is engaging and
has not failed. See Brew Switch Adjustment
●
Check that the pump relay in the electrical box functions correctly.
●
Pump relay may have timed out.(BRPR0#) Turn group off to reset.
No Water Flow
While Pump is on
●
Check in the group top that the brew solenoid switch is engaging and
has not failed. See Brew Switch Adjustment section for more info.
●
Brew Solenoid is stuck closed (may be caused by soap residue not fully
flushed after cleaning).
●
Brew Solenoid coil may have failed. Check that coil magnetizes when
group is in preinfuse and brew positions.
●
Jet may be plugged. See Jet Clearing Procedure
●
Water filter may be plugged. Check and Replace if necessary.
●
Brew valve may have timed out.(BRBV0#) Turn brew group off to reset.
Slow Water Flow
(more than 10
seconds to pour 2
ounces of water)
●
Debris is stuck in the water flow restrictor jet. See Jet Cleaning Proce-
dure.
●
Water filter may be clogged and should be changed
Brew Gauge Flut-
ters or Vibrates
●
Water is in the gauge or tube. Remove the gauge and tube, blow out
the water, and reinstall. Machines made after #240 use a thinner, longer
gauge tube which eliminates flutter. If your machine is made before #240
and this issue becomes unacceptable, contact your dealer, service pro-
vider, or the Synesso™ factory to purchase a retrofit tube.
Brew Tem-
perature
Readout for Brew
Water Temperature
Varies by a Few
Degrees
●
The control must detect a temperature one increment (0.5°F on original
machines, or 0.1°F on current machines) above the set point before it
sends a signal to turn off the heating element. This will allow the elec-
tronics to show a reading just above the set point. The energy from the
heating element and the tube for the preheated incoming water are within
1” (25mm) from the location of the temperature probe in the brew tank.
The pickup tube for brew water is at the top of the brew group and is in
the most temperature stable water in the tank. The readout can show a
temperature of a few degrees above your set point, but your brew water
is actually at the set point.
Brew Temperature
Reads Low
(error: BRUT0#)
Be sure to allow 20 - 40 minutes from the time the machine is powered up
as the temperatures need to stabilize. Ambient temperature and airflow
can change how quickly the machine reaches stability.
Check that the element breaker is in the ON position
Check that the fuse on the power board, as well as the relay, are both
functioning properly.
Check that the brew tank thermal overload switch has not been tripped
Check that the connection to the temperature probe is intact and secure.
Make sure the set point has not been changed.
Brew Temperature
Reads High
(error: BROT0#)
Display temperature will climb during brewing as hot water from the
steam tank heat exchanger enters the brew tank. This is normal, and the
water dispensed will be at your set point, not the displayed temperature.
Содержание Cyncra
Страница 1: ...Technical Manual ...
Страница 9: ...9 INSTALLATION ...
Страница 19: ...HYDRAULIC SCHEMATIC SINGLE INLET 19 ...
Страница 20: ...HYDRAULIC SCHEMATIC HYDRA 20 ...
Страница 31: ...31 ELECTRICAL SYSTEM ELECTRICAL SCHEMATIC ...
Страница 38: ...38 ...
Страница 39: ...39 ...
Страница 40: ...40 ...
Страница 41: ...41 ...
Страница 43: ...43 ...
Страница 44: ...44 ...
Страница 45: ...45 ...