![Synesso Cyncra Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/synesso/cyncra/cyncra_technical-manual_1420884054.webp)
54
PROGRAMMING
Menu Level 3: PID Tune
Line 1 indicates that you are on the PID Tune screen. The proportional–integral–derivative controller
(PID controller) is a sequence of algorithms using separate, finely tuned parameters to achieve a
desired set point.
Synesso™ strongly recommends against altering these parameters.
Line 2 indicates the P Gain (Proportional Gain) value.
Line 3 indicates the I Gain (Integral Gain) value.
Line 4 indicates the D Gain (Derivative Gain) value.
The default values are shown in the picture above.
Menu Level 3: Serial Number
The Machine Serial Number is the designated identification given to the machine according to the
month/year and order of completion.
This method of identification may be used to help diagnose any issues or determine any specific
needs that may arise during the life of this machine. For this reason, the machine serial number
should not be altered.