1-8-15
T4300MTI
MECHANICAL TROUBLE INDICATOR
1, Each Malfunction Indication
If the MONITOR is turned ON right after the Mechani-
cal Malfunction occurs or POWER SAFETY/X-RAY is
turned ON, display the following character to show
Malfunction after the EJECT display.
Example: If REEL Malfunction
2, Each Malfunction evaluation
method
X-RAY protect
If X-RAY port becomes continuously 2.5V or more for
120 msec. (4 times 40 msec. interval), the unit shall
immediately turn OFF the POWER/MONITOR and
switch over to the Mechanical Malfunction mode with
POWER OFF.
(To return from this mode shall become possible only
by POWER Key as in the case of the Mechanical Mal-
function).
POWER SAFETY
1) POWER SAFETY 1
If P-SAFETY 1 port becomes continuously 2.5V or
less for 120 msec. (4 times 40 msec. interval) when
MONITOR is ON, the unit shall be assumed to be
the Power Malfunction 1 and immediately turn OFF
the POWER/MONITOR and switch over the
Mechanical Malfunction mode with POWER OFF.
(Shall not unload)
(To return from this mode shall become possible
only by POWER Key as in the case of the Mechan-
ical Malfunction).
* However the POWER SAFETY 1 function shall
be disabled during 500 msec. right after the MONI-
TOR turns ON.
2) POWER SAFETY 2
If P-SAFETY 2 port becomes continuously 2.5V or
less for 120 msec. (4 times 40 msec. interval) when
P-ON-H port is ON, the unit shall be assumed to be
the Power Malfunction 2 and immediately turn OFF
the POWER/MONITOR and switch over the
Mechanical Malfunction mode with POWER OFF.
(Shall not unload)
(To return from this mode shall become possible
only by POWER Key as in the case of the Mechan-
ical Malfunction).
* However the POWER SAFETY 2 function shall
be disabled during 500 msec. right after the P-ON-
H turns ON.
3) POWER SAFETY 3
If P-SAFETY 3 port becomes continuously 2.5V or
over for 120 msec. (4 times 40 msec. interval)
when MONITOR is ON, P-SAFETY 3 function is
available. After that, if P-SAFETY 3 port becomes
continuously 2.5V or less for 120 msec. (4 times 40
msec. interval), the unit shall be assumed to be the
Power Malfunction 3 and immediately turn OFF the
POWER/MONITOR and switch over the Mechani-
cal Malfunction mode with POWER OFF.
(Shall not unload)
(To return from this mode shall become possible
only by POWER Key as in the case of the Mechan-
ical Malfunction).
* However the POWER SAFETY 3 function shall
be disabled during 500 msec. right after the MONI-
TOR turns ON.
Immediately preceding
Malfunction
Display character
REEL Malfunction
R
DRUM Malfunction
D
CASSETTE LOADING Mal-
function
C
TAPE LOADING Malfunction
T
P-SAFETY 1
1
P-SAFETY 2
2
P-SAFETY 3
3
X-RAY
X
EJECT R
Содержание FUNAI SYLVANIA Emerson 6309CC
Страница 19: ...1 6 2 T4300DC Fig 1 S 1 S 2 S 2 S 1 ANT DC 13 2V AC 120V 1 REAR CABINET S 1 S 1 S 1 S 1 S 2 S 2 Fig 2...
Страница 21: ...1 6 4 T4300DC Fig 4 CRT CBA S 8 S 8 S 8 ANODE CAP 8 CRT...
Страница 86: ...Packing X16 TAPE S1 X6 X22 X21 X2 X4 X3 A4 S6 S3 S3 S2 S2 PACKING TAPE X1 S4 X7 3 1 7 T4300PEX...
Страница 107: ...Printed in Japan 2002 03 25 HO SC309C F3809U F3809C 6309CC EWC0902 SSC092 T4300UA 4321UB 4301UB 4302UC 4303UD 4304UE...