1-8-16
T4300MTI
Mechanical Malfunction determination
1) REEL Malfunction detection
Countermeasure for REEL and CAPSTAN motor
rotation malfunction (Except CASSETTE LOAD-
ING function)
After the Malfunction detection with REEL/CAP-
STAN sensor, the unit shall switch over to STOP
(B) and be REEL Mechanical Malfunction.
a) If the T-REEL pulse is not impressed after a lapse
of 5 sec. at SP, 10 sec. at LP, 14 sec. at SLP, or
more in the REEL Rotation Mode like PLAY/REC,
FS/RS Mode, and the T-REEL or S-REEL pulse is
not impress after a lapse of 4 sec. or more in REEL
Rotation Mode of FF/REW, it shall be assumed to
stop the rotation and switch over to STOP (B) posi-
tion, then POWER be turned OFF and the unit be
REEL Mechanical Malfunction. (T-REEL and S-
REEL for the models on S-REEL and only T-REEL
for other models)
b) If the C-FG pulse is not impressed for a lapse of 1
sec. or more during the CAPSTAN MOTOR rota-
tion, it shall be MOTOR Rotation Malfunction
(REEL Malfunction).
2) DRUM Malfunction detection
Detect the DRUM rotation at the D-FG input termi-
nal.
If the variation of D-FG input level is not detected
for a lapse of 1 sec. or more when D-CONT is "H",
it shall be assumed to be Rotation Malfunction and
be DRUM Malfunction.
When detect Drum Malfunction, POWER shall be
turned OFF after the unit switches over to STOP
(B) Mode.
3) Countermeasure for TAPE LOADING Malfunction
Detect the Malfunction with the LOADING Switch.
a) TAPE LOADING Malfunction
If LD-SW does not go to the established position
after a lapse of 7 sec. or more from TAPE LOAD-
ING or TAPE UNLOADING start, the LOADING
function shall immediately be stopped and POWER
be turned OFF, and inform the Timer about the
LOADING Mechanical Malfunction.
b) LD-SW Position Malfunction at each mode
When the unit operates at each mode, even if the
LD-SW position changes from the established one
in its mode, it keeps the function according to its
mode.
4) Countermeasure for CASSETTE LOADING Mal-
function
a) CASSETTE IN operating Malfunction
If LD-SW does not go to SB position after a lapse
of 5 sec. or more from the CASSETTE insertion
start, the unit starts the CASSETTE OUT opera-
tion.
After switch over to CASSETTE OUT operation
and then a laps of 5 sec. or more from the CAS-
SETTE OUT operation start, if LD-SW does not go
to the EJ position or if START Sensor and END
Sensor does not turn "ON" at the EJ position, the
unit starts again to insert CASSETTE.
(However in S-INH state, the START/END Sensor
shall be disabled).
b) CASSETTE OUT operating Malfunction
After a lapse of 5 sec. or more from CASSETTE
OUT operation start, if LD-SW does not go to the
EJ position or if START Sensor and END Sensor
does not turn "ON" at the EJ position, the unit starts
to insert CASSETTE.
(However in S-INH state, the START/END Sensor
shall be disabled).
When the unit switches over to CASSETTE inser-
tion at CASSETTE IN or CASSETTE OUT Mal-
function, if LD-SW does not go to the SB position
after a lapse of 5 sec. or more from CASSETTE
insertion start, the function shall immediately be
stopped and POWER be turned OFF, and the unit
be CASSETTE LOADING Malfunction.
c) When POWER is turned ON, if the CL position or
GC position cannot be detected after 5 sec. LD-
REV operation and 5 sec. LD-FWD operation, the
function shall immediately be stopped and POWER
be turned OFF, and the unit be CASSETTE LOAD-
ING Malfunction.
d) When POWER is turned ON without CASSETTE
(EJ position) and LD-SW is monitored all the time,
if the CL or GC position is detected continuously for
1 sec. or more, the POWER shall be turned OFF
and the unit be CASSETTE LOADING Malfunction.
Countermeasure for Mechanical
Malfunction
If the unit detects Mechanical Malfunction, turn the
POWER OFF. If the unit is Mechanical Malfunction,
Key input except POWER key shall be disabled and
CASSETTE insertion disabled. When POWER Key is
entered, the POWER is turned ON and the unit
switches over the EJECT Mode. (Return with POWER
ON)
Содержание FUNAI SYLVANIA Emerson 6309CC
Страница 19: ...1 6 2 T4300DC Fig 1 S 1 S 2 S 2 S 1 ANT DC 13 2V AC 120V 1 REAR CABINET S 1 S 1 S 1 S 1 S 2 S 2 Fig 2...
Страница 21: ...1 6 4 T4300DC Fig 4 CRT CBA S 8 S 8 S 8 ANODE CAP 8 CRT...
Страница 86: ...Packing X16 TAPE S1 X6 X22 X21 X2 X4 X3 A4 S6 S3 S3 S2 S2 PACKING TAPE X1 S4 X7 3 1 7 T4300PEX...
Страница 107: ...Printed in Japan 2002 03 25 HO SC309C F3809U F3809C 6309CC EWC0902 SSC092 T4300UA 4321UB 4301UB 4302UC 4303UD 4304UE...