12713140-003-2 Revision E.01 – January 2007
SSU-2000e Technical Reference
51
Chapter 2 TL1 Reference
Retrieve DS1/E1 Input Parameters
Retrieve DS1/E1 Input Parameters
This command returns the settings for the DS1 or E1 Input module or port
designated by the aid.
Syntax
RTRV-PRMTR-INPUT:[tid]:[aid]:ctag;
Response Format
^^^"aid:pstate,pri,pql,mode,ssm,zs,crc,gain,csflt,bit" <cr lf>
where:
aid
= module or port access identifier
pstate
= port enabled state [ON | OFF]
pri
= priority 1 (highest) through 10 (lowest) or MON for monitor
pql
= provisioned priority quality level [1 – 16]
mode
= framing type or clock frequency in MHz: [ESF | D4 | CCS | CAS | 1 | 1.544
|2.048 | 5 | 10]
ssm
,
zs
,
crc
, and
gain
= [ON | OFF]
csflt
= Cesium fault [HI | LO | OFF | NA]
bit
= bit number 4 through 8 of the Time Slot 0 word used for the E1 sync status
message
Related Commands
Parameter
Value
Description
[aid]
ALL
Retrieves the parameters from all DS1 or E1 Input
modules in the shelf.
SxAy[-z]
Retrieves parameters from the specified DS1 or E1 Input
module [or port].