Chapter 8 Default Settings
DS1 and E1 Input Module Default Settings
310
SSU-2000e Technical Reference
12713140-003-2 Revision E.01 – January 2007
MTIE Limits for the DS1 Input Module
provides MTIE limits for the DS1 Input Module configuration and factory
defaults and settings.
Cesium Fault Nominal
Off
Low/High/Off
Gain
Off
On or Off (20 dB)
Input Signal Error Limit
(LOS, AIS, OOF, BPV,
CRC)
Defaults are:
LOS:
10 seconds (Err Cnt)
5 seconds (Clr Cnt)
AIS:
12 seconds (Err Cnt)
5 seconds (Clr Cnt)
OOF:
14 seconds (Err Cnt)
5 seconds (Clr Cnt)
BPV, CRC:
16 seconds (Err Cnt)
5 seconds (Clr Cnt)
1 to 100 for LOS and AIS
1 to 10 000 for BPV, CRC and
OOF
MTIE Limits
See
and
1 to 10 000
MTIE Limit 1 Alarm Mode
MINOR
Ignore, Report, Minor, Major, or
Critical
MTIE Limit 2 Alarm Mode
MAJOR
Ignore, Report, Minor, Major, or
Critical
Alarm Initial Severity
MINOR (except LOS and Level
2 MTIE, which are MAJOR)
Ignore, Report, Minor, Major, or
Critical
Alarm Initial Delay
0 s
0 to 86 400 s
Alarm Elevation Time
86 400 s
60 to 500 000 s, 0 is disabled
Port Status
Disabled
Enabled/Disabled
Port Name
Not applicable
Any string from 0 to 20 characters
Table 8-4. DS1 Input Module – MTIE Limits
Time (s)
Set Limit L1
(ns)
Set Limit L2
(ns)
Clear Limit L1
(ns)
Clear Limit L2
(ns)
10
260
325
230
290
100
440
550
400
490
Table 8-3. DS1 and E1 Input Module Default Configuration (Continued)
Configuration Setting
Factory Default
Range