12713140-003-2 Revision E.01 – January 2007
SSU-2000e Technical Reference 239
Chapter 4 NTP and SNMP
SNMP Protocol
Adding a User
TL1 Command
To use the TL1 command to add user XYZ with MD5 authentication using algorithm
HMAC-MD5 with the 16 character authentication key, a 16 character privacy key,
and user level 3, type:
SET-PRMTR-SNMPV3-USER:::::ADD,XYZ,MD5,123456789ABCDEFG,
123456789ABCDEFG,3;
ICS Command
To use the ICS command to add user XYZ with MD5 authentication using algorithm
HMAC-MD5 with the 16 character authentication key, a 16 character privacy key,
and user level 3, type:
SNMP V3USER ADD XYZ
and press
Enter
.
At the prompt, type
123456789ABCDEFG
(or any other 16-character authentication
key) and press
Enter
.
At the prompt, type
123456789ABCDEFG
(or any other 16-character privacy key) and
press
Enter
.
At the prompt, type
3
and press
Enter
.
Adding a Manager IP Address
You can add up to four managers in the SNMP manager table.
TL1 Command
To use the TL1 command to add an SNMP manager IP address for traps with
username XYZ, type:
SET-PRMTR-SNMPV3-MANAGER:::::ADD,192.100.100.100,XYZ;
Note:
Valid authentication key and privacy key characters include
numbers, upper and lowercase letters, and the character set
":;<=>?@". The semicolon functions properly only in ICS mode, and
the colon must be enclosed in quotes in TL1 mode, as “
USER:NAME
”
or
“
PASS:WORD
”. To enter lowercase letters, enclose the input in quotes, as
“
UserName
”
or
“
PassWord
”.
Do not
use spaces in usernames.
Note:
Valid authentication key and privacy key characters include
numbers, upper and lowercase letters, and the character set
":;<=>?@". The semicolon functions properly only in ICS mode,
and the colon must be enclosed in quotes in TL1 mode, as
“
USER:NAME
”
or
“
PASS:WORD
”. To enter lowercase letters,
enclose the input in quotes, as “
UserName
”
or
“
PassWord
”.
Do
not
use spaces in usernames.