Chapter 2 TL1 Reference
Set Operating Mode
142
SSU-2000e Technical Reference
12713140-003-2 Revision E.01 – January 2007
Set Operating Mode
This command sets the Operating Mode for the system.
Syntax
SET-PRMTR-OPERMODE:[tid]::ctag::mode;
where:
NORMAL = SSU is in normal master mode. In this mode, the unit selects an input
reference from any available input sources.
SUBTENDING = SSU is in ANSI subtending mode. In this mode, the unit
chooses an available Composite Clock Input as an input reference. All other
inputs shall not be selected as input reference.
Related Commands
Parameter
Format
Description
mode
normal |
subtending
Sets the operating mode.