5

ARC-2 and ARC-2i Menu ARCs

6408 216th Street SW 

|

 Mountlake Terrace, WA 98043  USA

T

 +1.425.778.7728  

F

 +1.425.778.7727 

|

 

www.symetrix.co

Menu ARC Features

Processor

Atmel ATmega 128

Field-Upgradeable Firmware

Yes

Number of Menus

24

Enumerations per Menu

16

Menu Range Limits

Yes

Maximum Characters per Menu Name

31

Maximum Number of Strings*

255

ARC Audio Support

Yes

115k RS-485 Baud Rate Support

Yes

Maximum Operating Voltage

30 VDC

*A “string” is equal to eight characters.

Overview

The ARC-2 and ARC-2i, known together 
as the Menu ARCs, are menu-driven 
remote controls for Symetrix DSPs.

 

Tap into the full power of your system with 
twenty-four (24) menus with up to sixteen 
(16) items each that can be used to address 
multiple basic functions or initiate complex 
logic-based control events: gain, preset 
triggering, source selection, room combining 

and more. The 8-character 
backlit display supports up 
to thirty-one (31) scrolling 
characters, providing 
instant user feedback 
for control assignments, 
default settings, and 
actions. The three buttons 
help you navigate menus, 
raise or lower values, 
and enable or disable 
the remote control. All 
control assignments, 
including item labeling, 
parameter limits and 
firmware version upgrades 
are handled by software 
included with Symetrix 
DSP hardware. Power, 

control, and a single channel of ARC Audio 
are connected via RJ-45 inputs or screw-

type barrier strips.

 Intuitive Navigation:

 

Pressing the menu button navigates through 
the menu names. The menu button also 
acts as a preset trigger when a preset list 
is scrolled. The up/down arrow buttons 
adjust parameter settings and scroll through 
preset lists. Holding the menu button and 
using the up/down arrow keys moves you 
forward or backward through the menus. 

Programmable Setup:

 The wall panel’s 

behavior is programmable as well. Menu 
brightness in “active” and “inactive” states 
can be set independently, so the display will 
“sleep” in light-sensitive environments like 
theaters. If the Menu ARC goes idle, it can 
scroll a message and return to the top of its 
menu tree. Upper and lower parameter limits 
help contain the range of adjustment and a 
button press lockout will prevent tampering 
by curious but unauthorized fingers. The 
ARC-2 features an aluminum faceplate and 
includes a power supply while the ARC-
2i features a white plastic faceplate and is 
powered directly by its host device, power 
supply not included. Both mount into a single 
gang electrical box (US).

ARC-2i

Pictured: 

the 

ARC-2

 (above) 

and the  

Integrator 
Series ARC-2i

 

(right).

Overview

Содержание ARC-2

Страница 1: ...ARC 2 and ARC 2i Menu ARCs Quick Start Guide ...

Страница 2: ...2 Quick Start Guide 6408 216th Street SW Mountlake Terrace WA 98043 USA T 1 425 778 7728 F 1 425 778 7727 www symetrix co Safety ...

Страница 3: ...aratus shall be connected to a mains socket outlet with a protective earthing connection Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outl...

Страница 4: ...ly for use with the ARC series of remotes DO NOT plug the ARC connectors on Symetrix products into any RJ 45 connector labeled SYMLINK ETHERNET or COBRANET The ARC RJ 45 connectors on Symetrix products can carry anywhere from 6 to 24 VDC which can damage SymLink Ethernet and CobraNet circuitry ARC ARC SYMLINK TRANSMIT RECEIVE COBRANET ETHERNET ETHERNET Warning ...

Страница 5: ...item labeling parameter limits and firmware version upgrades are handled by software included with Symetrix DSP hardware Power control and a single channel of ARC Audio are connected via RJ 45 inputs or screw type barrier strips Intuitive Navigation Pressing the menu button navigates through the menu names The menu button also acts as a preset trigger when a preset list is scrolled The up down arr...

Страница 6: ...Two sets of jumpers at J9 configure the grounding of the ARC Audio pair Refer to the legend below for positions Refer to the ARC Network Design section for more information J7 RS485 Termination Refer to the RS485 Termination section for more information S4 Device Address DIP Switches Configures the device s RS485 bus address Refer to the Device Addressing section for more information J8 RS485 Powe...

Страница 7: ...sume 28 gauge CAT5 cabling maximum stated distances assume 24 gauge CAT5 cabling If power is not distributed over CAT5 each RS 485 chain will be limited to 1000 ft in a star network configuration and 4000 ft in a daisy chain network configuration Longer distances may be possible using third party RS 485 extender products Disclaimer From time to time we test the compatibility of our own products wi...

Страница 8: ...or expander in to clean up the signal This technique does not provide much flexibility within the system design and therefore is not recommended Frequency response Frequency response can roll off due to the capacitance of a long cable run The amount of roll off is highly dependent on source impedance the output impedance of what is supplying the signal Most pro audio devices have low output impeda...

Страница 9: ...mNet Designer s Help for information on setting the RS 485 baud rate Note the Menu ARC s faceplate will need to be removed in order to access this jumper J10 is just below the menu display Menu ARC DIP Switch Settings NOTE For the sake of space a small variety of configurations are shown A total of 31 devices per RS 485 bus are possible ADDRESS 1 ADDRESS 2 ADDRESS 3 ADDRESS 4 ADDRESS 5 ADDRESS 7 A...

Страница 10: ...tration of a typical SymNet Network Audio Solution shows the place of the ARC PS in a large multi purpose network audio solution Restaurant Bar Banquet Meeting Rooms Lobby Wall Panel controls local volume source selection and time of day presets Wall Panels control local room BGM sources BGM and Mic volumes Wall Panels link when rooms are combined Wall Panel selects paging zones Restaurant Applica...

Страница 11: ...uter Said software is specifically excluded from this warranty Limitation of Liability The total liability of Symetrix on any claim whether in contract tort including negligence or otherwise arising out of connected with or resulting from the manufacture sale delivery resale repair replacement or use of any product will not exceed the price allocatable to the product or any part thereof which give...

Страница 12: ...esponsibility with regard to the performance or use of these products Under copyright laws no part of this brochure may be reproduced or transmitted in any form or by any means electronic or mechanical without permission in writing from Symetrix Inc If however your only means of access is electronic permission to print one copy is hereby granted The following are either Trademarks or Registered Tr...

Отзывы: