7-16
MS-804FZY and MS-904HS Integration Guide
Timeout Between Decodes
Timeout Between Decodes, Same Symbol
Parameter # 89h
When in Continuous triggering mode, this parameter sets the minimum duration of not
decoding data before the scanner decodes a second bar code identical to one just
decoded. This reduces the risk of accidently scanning the same symbol twice. It is
programmable in 0.1 second increments from 0.0 to 9.9 seconds. The recommended
interval is 0.6 seconds.
Timeout Between Decodes, Different Symbol
Parameter # 90h
This option sets the minimum duration of not decoding data before the scanner decodes a
second (different) bar code. This is used in continuous-on mode to prevent the beeper from
beeping when a different symbol appears in the scanner’s field of view before the timeout
period between decodes expires. This is programmable in 0.1 second increments from 0.0
to 9.9 seconds. The recommended value is 0.0 seconds.
Select the timeouts between decodes for the same or different symbols.
1. Scan the option bar code you wish to set.
2. Scan two numeric bar codes beginning on
which correspond to the
desired interval, in 0.1 second increments.
Содержание MiniScan MS-804FZY
Страница 1: ...MiniScan MS 804FZY and MS 904HS Integration Guide...
Страница 2: ......
Страница 3: ...MiniScan MS 804FZY and MS 904HS Integration Guide 72 58197 01 Revision A September 2003...
Страница 10: ...viii MS 804FZY and MS 904HS Integration Guide...
Страница 16: ...xiv MS 804FZY and MS 904HS Integration Guide...
Страница 58: ...5 4 MS 804FZY and MS 904HS Integration Guide...
Страница 151: ...7 91 Parameter Menus Baud Rate continued Baud Rate 4800 05h Baud Rate 9600 06h Baud Rate 19 200 07h 38 400 08h...
Страница 166: ...7 106 MS 804FZY and MS 904HS Integration Guide Numeric Bar Codes continued 4 5 6 7...
Страница 168: ...7 108 MS 804FZY and MS 904HS Integration Guide...
Страница 172: ...9 2 MS 804FZY and MS 904HS Integration Guide...
Страница 182: ...Index 4 MS 804FZY and MS 904HS Integration Guide...
Страница 183: ......