Calculate usable scan length as follows (see
L = 2 x (D+d+B) x Tan (A/2)
where:
D = Distance (in inches) from the front edge of the host housing to the bar
code.
d = The host housing’s internal optical path from the edge of the housing to the
front of the MiniScan scanner.
B = Internal optical path from the scan mirror to the front edge of the MiniScan
scanner.
A = Scan angle in degrees.
Note:
Usable scan length determined by this formula, or 90% of scan line
at any working distance. This formula is based on good quality
symbols in the center of the working range and length of bar code.
Table 2-1. Calculation Constants
Constants
B
A
MS-804FZY
0.89
46.5°
MS-804FZY (Narrow)
0.89
35°
MS-904HS
0.77
37°
Содержание MiniScan MS-804FZY
Страница 1: ...MiniScan MS 804FZY and MS 904HS Integration Guide...
Страница 2: ......
Страница 3: ...MiniScan MS 804FZY and MS 904HS Integration Guide 72 58197 01 Revision A September 2003...
Страница 10: ...viii MS 804FZY and MS 904HS Integration Guide...
Страница 16: ...xiv MS 804FZY and MS 904HS Integration Guide...
Страница 58: ...5 4 MS 804FZY and MS 904HS Integration Guide...
Страница 151: ...7 91 Parameter Menus Baud Rate continued Baud Rate 4800 05h Baud Rate 9600 06h Baud Rate 19 200 07h 38 400 08h...
Страница 166: ...7 106 MS 804FZY and MS 904HS Integration Guide Numeric Bar Codes continued 4 5 6 7...
Страница 168: ...7 108 MS 804FZY and MS 904HS Integration Guide...
Страница 172: ...9 2 MS 804FZY and MS 904HS Integration Guide...
Страница 182: ...Index 4 MS 804FZY and MS 904HS Integration Guide...
Страница 183: ......