fig. 14

fig. 15

   

4. Use the SCREW FOR WALL to attach the other end of SAFETY CABLE to the wall.

5. Make sure all screws are tight.

OPERATION

After reading complete instructions, confirm all controls on fireplace are in the OFF 
position. Plug the fireplace into a 15AMP/120Volt outlet. If the cord does not reach, 
you may use an extension cord rated for a minimum of 1875 WATTS. Once the 
fireplace insert has been properly connected to a grounded electrical outlet, it is ready 
to operate.

OPERATION BY THE CONTROL PANEL 

The controls are located behind the grill below the front glass and can be accessed by 
pulling the grill from the top, forward and down.

ON/OFF: Press this button for main power and flame effect. The indicator light will 
turn on. See below for other control switches.

750W: For low heat function - Press this switch while the ON/OFF switch is in the on 
position for low heat. The indicator light will turn on.

1500W: For high heat function - Press this switch while the ON/OFF switch  and the 
750W switch are in the on position for high heat. The indicator light will turn on.

Temperature Control: To adjust the temperature to your individual requirements, turn 
the temperature control dial to the right (clockwise) to increase the desired tempera-
ture and to the left for lower temperature. This temperature control dial can only be 
used while the ON/OFF switch and 750W & 1500W switches are in the ON position. 
When the heater reaches to the desired temperature, the heater and 750W/1500W 
indicator light will off but the fan still keeps working with air flow. Adjust this knob to 
restart the heater.

Dimmer Control Knob: Turn the dimmer dial clockwise or counter clockwise to get 

the desired flame intensity. The dimmer switch can only be used when the ON/OFF 
switch is in the on position.

Note: When the ON/OFF switch is turned off, all other heater functions will stop 

even though the switches may be in the on position. 

MAINTENANCE

NOTE: IN ORDER TO SHUT DOWN THE HEATER SAFELY, IT IS 

RECOmmENDED TO TURN THE TEmPERATURE CONTROL KNOB TO 

LOWEST SETTING AND ALLOW THE HEATER TO COOL DOWN BEFORE 

PRESS THE ON/OFF SWITCH TO OFF POSITION.

MAINTENANCE WARNING:  

Disconnect power and unplug the power cord before attempting any maintenance or 
cleaning to reduce the risk of fire, electric shock or damage to persons. The bulbs in 
your unit can become extremely hot. Allow at least 10 minutes between turning off 
the unit and removing the light bulbs to avoid the accidental burning of the skin.

RISK OF FIRE: DO NOT ExCEED THE RECOmmENDED BULB WATTAGE. 

REPLACING THE  LIGHT BULBS

Step 1:  Remove 4 screws on the back of fireplace and remove the rear cover  
 

of the unit. 

Step 2:  You will find 1 X 40W Type B-10 bulbs under log-set bed.

Step 3:   Loosen and remove burnt out bulb and replace with new bulb.

Step 4:  Close the rear cover and secure with the 4 screws.

Step 5:  Plug in the unit.

Содержание SQCM480AT-38CACO

Страница 1: ...ause a risk of fire However if you have to use an extension cord the cord shall be No 16AWG minimum size and rated not less than 1875 watts 16 Do not plug this product into a receptacle controlled by...

Страница 2: ...s Head Screwdriver Electri Drill Drill bit 5 16 inches 8mm Hammer CAUTION Place a piece of cardboard or protective sheet on the floor in order to avoid scratching the decorative surface of your mantle...

Страница 3: ...RIGHT SIDE H with 2 MEDIUM KD SCREWS V See Fig 5 fig 5 Step 6 Attach the LEFT SIDE E G and M and RIGHT SIDE F H and N to the BASE B using 4 MEDIUM KD SCREWS V See Fig 6 fig 6 Step 7 Mount the LOWER FR...

Страница 4: ...4 MEDIUM KD SCREWS V as shown in Fig 13 fig 13 Step 3 Tighten all screws Step 4 Move assembled unit to desired location Unit should not be positioned in area exposed to direct sunlight WALL ANCHOR SA...

Страница 5: ...used while the ON OFF switch and 750W 1500W switches are in the ON position When the heater reaches to the desired temperature the heater and 750W 1500W indicator light will off but the fan still kee...

Страница 6: ...s when using power tools Option 1 Use the spare KD NUTS KDSCREWS and PLASTIC CONNECTOR 1 Place the PLASTIC CONNECTOR on the mantel unit and mark the drill holes as shown in fig B fig B 2 Drill the hol...

Страница 7: ...before it leaves the factory and it is guaran teed for one year If the unit should fail to operate correctly within one year from the date of purchase call customer service at 1 800 459 4409 EST We wi...

Страница 8: ......

Страница 9: ...ets y p n trer ce qui risquerait de provoquer une d charge lectrique ou un incendie ou d endommager l appareil 12 Pour viter les risques d incendie ne bloquez en aucune fa on les prises d air de l app...

Страница 10: ...MENT LISTE DES PI CES QTY A Panneau sup rieur 1 B Panneau inf rieur 1 C Panneau sup rieur avant 1 D Centre avant 1 E Avant gauce 1 F Avant droit 1 G Panneau gauche 1 H Panneau droit 1 I Support triang...

Страница 11: ...NEAU AVANT DROIT F avec deux VIS KD MOYENNES V Reportez vous la figure 4 fig 4 tape 5 Fixez le PANNEAU AVANT GAUCHE E au PANNEAU LAT RAL GAUCHE G avec deux VIS KD MOYENNES V Fixez le PANNEAU AVANT DRO...

Страница 12: ...vous la figure 10 fig 10 tape 11 Installez le HAUT A sur l unit avec 3 VIS KD MOYENNES V tel qu indiqu la figure 11 fig 11 tape 12 Serrer toutes les vis INSTALLATION DE L INSERTION DU FOYER L insertio...

Страница 13: ...en tirant la grille par sa partie sup rieure vers l avant et vers le bas MARCHE ARR T appuyez sur ce bouton pour la puissance principale et l effet de flamme La lumi re indicatrice s allumera Voir pl...

Страница 14: ...puis enlever le couvercle tape 2 Vous trouverez deux 1 ampoules de 40 W de type B 10 sous l assise des b ches artificielles tape 3 Enlever l ampoule et remplacer par une neuve tape 4 Referme le couve...

Страница 15: ...fon deur sur le manteau 4 trous sont n cessaires pour chaque PETIT SUPPORT EN L Reportez vous la figure G fig G 3 Fixez le PETIT SUPPORT EN L et maintenez le en place avec les VIS comme montr la figur...

Страница 16: ...port pay l appareil r par ou un appareil neuf L unique obligation de la compagnie ce titre est de r parer ou de remplacer l appareil La pr sente garantie est d clar e nulle si de l avis de Quality Cra...

Страница 17: ...producir una descarga el ctrica un incendio o da ar el calentador 12 Para impedir que se produzca un incendio no bloquee las entradas o salidas de aire No ponga el calentador sobre superficies blanda...

Страница 18: ...anel superior 1 B Panel inferior 1 C Panel frontal superior 1 D Frente medio 1 E Panel frontal izquierdo 1 F Panel frontal derecho 1 G Lateral izquierdo 1 H Lateral derecho 1 I Soporte triangular izqu...

Страница 19: ...O N al PANEL DELANTERO DERECHO F con dos 2 TORNILLOS KD MEDIANOS V Vea la fig 4 fig 4 Paso 5 Sujete el PANEL DELANTERO IZQUIERDO E al PANEL LATERAL IZQUIERDO G con 2 TORNILLOS KD MEDIANOS V Sujete el...

Страница 20: ...S Q Vea la fig 10 fig 10 Paso 11 Instale la CUBIERTA A en la unidad con 3 TORNILLOS KD MEDIANOS V como se muestra en la fig 11 fig 11 Paso 12 Apriete todos los TORNILLOS INSTALACI N DEL DISPOSITIVO IN...

Страница 21: ...seg rese de que todos los tornillos queden ajustados FUNCIONAMIENTO Despu s de leer las instrucciones verifique que todos los controles de la chimenea est n a la posici n APAGADO Enchufe la chimenea a...

Страница 22: ...rsonales Las bombillas en la unidad pueden calentarse mucho Para evitar quemaduras acciden tales de la piel deje pasar por lo menos 10 minutos despu s de haber apagado el aparato para quitar las bombi...

Страница 23: ...gujeros de perforaci n en la repisa como se muestra en la fig F fig F 2 En la repisa perfore agujeros de 2 mm 1 16 in de di metro y de 8 mm 5 16 in de profundidad Cada SOPORTE LARGO PEQUE O necesita 4...

Страница 24: ...idad nueva tambi n con flete pago La nica obligaci n de la empresa es reparar o cambiar la unidad Esta garant a carece de validez si a criterio de Quality Craft la unidad ha sido manipulada alterada u...

Отзывы: