Chart 1: DIP SWITCHES
DIP 1
Alarm timing
DIP 2
Polarity of alarm input
DIP 3
Polarity of flash input
DIP 4
Control panel ON/OFF indication
DIP 5
Sounder and Flash activation mode
DIP 6
Sounder and Flash activation mode
DIP 7
Max number of alarms per day
DIP 8
Tone selection
Chart 2: ALARM DURATION
DIP 1
ALARM TIMING
ON
(default sitting)
3 minutes
OFF
8 minutes
Chart 3: WIRING
TERMINALS
CONNECTION
1
Negative power supply 0V GND
2
Positive power 13.8V
3
Sounder control (Chart 4)
4
Flash control (Chart 5)
5
ON/OFF indication
6
Anomaly output. Open collector, 0V = anomaly
7
Output for connection of the flash memory
input with a dry contact (volt-free)
8
N.C. self-protection
9
N.C. self-protection
Chart 4: SOUNDER INPUT POLARITY
DIP 2
TERMINAL 3
SOUNDER STATE
ON
(default setting)
+12V
Silence
Not connected or 0V (Positive-missing)
Alarm
OFF
+0V
Silence
Not connected or +12V (Negative-missing)
Alarm
SITTING
Chart 5: FLASH INPUT POLARITY
DIP 3
TERMINAL 4
FLASH
BEHAVIOUR
ON
(default
setting)
Not connected or 0V
Flashing
12V
Blocked
OFF
Not connected or 12V
Flashing
0V
Blocked
Chart 6: CONTROL PANEL ON/OFF INDICATION
DIP 4
TERMINAL 5
FLASH BEHAVIOUR (ON/OFF)
ON
(default
setting)
+12V
All LEDs flash 3 times
Not connected or 0V
All LEDs stay on for 4 seconds, then
switch off
OFF
+12V
All LEDs flash 3 times and 1 LED
keeps on flashing
Not connected or oV
All LEDs stay on for 4 seconds and
then switch off
Chart 7: SOUNDER AND FLASH ACTIVATION
DIP 5
DIP 6
SOUNDER CONDITION
FLASH CONDITION
ON
(default setting)
ON
(default setting)
Controlled by Terminal 3
T. 4 arms – T. 3 starts – T.4 disarms and stops
OFF
ON
Controlled by Terminal 3 Starts with T. 3 and stops with 1 pulse to T. 4 flash reset
ON
OFF
Controlled by Terminal 3
Controlled by T. 3
OFF
OFF
Controlled by Terminal 3
Starts with T. 4 and stops with T. 4 (indipendent)
DIP SWITCHES SETTING
DIP switches can be moved only within the first 12 hours after the board is powered. After this period,
DIP switches settings will be stored and any further switching will be useless.
By disconnecting battery and power supply, DIP switches will return to active for another 12 hours.