2
INSTALLATION MANUAL
SELF-SUPPLIED SOUNDER MODEL FOR OUTDOOR USE
models ECO 800, ECO 800 LS, ECO 800 X, ECO 800 LSX
ECO 800/ECO 800 X description:
self-supplied outdoor sounder with high-brightness low-consumption
LED flashing unit – tamper against sounder opening and against any attempts of removing the sounder
from the wall – programmable sounds and timings – alarms counting – microprocessor self-check
of battery and speaker with corresponding negative anomaly output – possibility to manage sound
and flash independently – flash reset input – momentary and permanent signaling of system ON/OFF
(arming/disarming) – electronic circuit protected against polarity inversion and tropicalized through a
special resin-immersion process to resist even in very humid installation locations and in case of bad
weather conditions – external cover in painted zinc-plated steel or stainless steel – base and internal
cover in painted steel – removal, opening, foam and shock tamper devices are series-connected and, in
case of tampering attempt, they provide the corresponding notice by opening the contact between the
two TAMPER terminals.
ECO 800 LS/ECO 800 LSX description:
technical features as per ECO 800/ECO 800 X models, with
double micro anti-foam anti-stock device against hard hits.
TECHNICAL FEATURES
Voltage
Nominal voltage of battery recharge
13.0
÷
13.8 V
Minimum power supply
10 V
Maximum power supply
15 V
Sound and flash alarm voltage
< 2.0 e > 3.5 V (MAX 13.8V)
Sound and flash block voltage
> 2.0 e < 3.5 V (MAX 13.8V)
Current
Max consumption from control panel (during
recharge and/or sound)
500mA
±
100mA
Battery consumption when the sounder is in
alarm
1.3A +100/-300mA
Flashing unit consumption
90mA
±
10mA
Consumption in stand-by
15mA
Consumption from control inputs
+0,5mA @Vc=12V; -0,3mA @Vc=0V
Open collector
-10mA Max
Sounds frequency
See CHART 9
Sound pressure
See DIAGRAM 1
LED flashing unit life
1,000,000 flashes
Sounder timing
3 minutes/8 minutes
Batteries
Housing capacity
12 V – 1.2 Ah or 2.2 Ah
Duration in stand-by
120 hours with 12V 2.2 Ah
Tamper-switch
N.C. 0.2 A max.; cover opening/sounder removal from wall