EN
24
Subindex 6b
Subindex 6b refers to the Fixed frequency 4 (P107). The value is given in Hz.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:6b
fix_freq_4
Variable
Unsigned16
rw
no
Subindex 6e
Subindex 6e refers to DIN1 (P110).
Value
Selection inverter
0000
hex
Off
803b
hex
Start/Stop
803c
hex
Stop
NOTE: See also Operating Manual Operating Software SycoDrive for HF Inverters e
@
syDrive 4624, 4625, 4626.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:6e
dig_in_1
Variable
Unsigned16
rw
no
Subindex 6f
Subindex 6f refers to DIN2 (P111).
Value
Selection inverter
0000
hex
Off
803d
hex
Start impulse
803e
hex
Reset
803f
hex
Speed direction
NOTE: See also Operating Manual Operating Software SycoDrive for HF Inverters e
@
syDrive 4624, 4625, 4626.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:6f
dig_in_2
Variable
Unsigned16
rw
no
Subindex 70
Subindex 70 refers to DIN3 (P112).
Value
Selection inverter
0000
hex
Off
803e
hex
Reset
803f
hex
Speed direction
8040
hex
Motor code bit 0
NOTE: See also Operating Manual Operating Software SycoDrive for HF Inverters e
@
syDrive 4624, 4625, 4626.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:70
dig_in_3
Variable
Unsigned16
rw
no
Subindex 71
Subindex 71 refers to DIN4 (P113).
Value
Selection inverter
0000
hex
Off
803e
hex
Reset
803f
hex
Speed direction
8040
hex
Motor code bit 1
NOTE: See also Operating Manual Operating Software SycoDrive for HF Inverters e
@
syDrive 4624, 4625, 4626.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:71
dig_in_4
Variable
Unsigned16
rw