SPEEDCUT
50
1 Phase 240V +/- 15%
MIN GENERATOR
(8.5kVA at 0.8 PF)
MIN 100 L/m - 75 psi
ERROR
FOR CONSUMABLES & SUPPORT GO TO WWW.SWSWELDING.COM.AU
DISPLAY CODES
ERROR! Under Pressure
ERROR! Missing Shield Cup
ERROR! Missing Electrode or Nozzle
ERROR! Over Temperature
QUICK REFERENCE GUIDE
CONTROL DIAL FUNCTIONS
NEGATIVE CENTRAL TORCH LEAD PORT
AIR INLET FITTING (ON BACK OF MACHINE)
ON/OFF SWITCH (ON BACK OF MACHINE)
POSITIVE GROUND CLAMP CABLE PORT
OPERATORS MANUAL
When illuminated refer to error code on display and resolve.
Amperage control/Press for 2 seconds for air test press to stop.
Read operators manual before use - download from
swswelding.com.au
Air pressure is below 60 PSI.
Shield cup is damaged or missing; torch lead is not connected
securely (Inspect & replace or install).
Electrode or nozzle is excessively worn or missing (Inspect & replace or install).
Machine has reached duty cycle limit allow to cool.
CAUTION! Only use clean, dry air for optimum
cutting performance and to prevent premature
servicing of internal regulator filter.
CAUTION! Ensure compressor/gas regulator
pressure is set between 75 - 100 PSI.
Exceeding 100 PSI can damage the internal
regulator.
Move to different mains power outlet, eliminate
or reduce extension lead, use higher output
generator, reduce cutting amperage.
™
i
i
POWER
When illuminated the power source is on.
i
O.T
When illuminated machine is over temperature, do not turn
off and allow to perform cooling cycle.
i
i
DIGITAL DISPLAY
Amperage setting , real time amperage display, error codes.
i
i
i
i
i
i
ERROR! Over Voltage
Incorrect input voltage supplied damage may have been caused.
Contact support if persists.
50
CAUTION! If the mains power supply/generator
is not sufficient, the machine will not maintain
a cutting arc, and it may damage the
power source.