6.  Trouble Shooting

In case LED 1 should not light up even during a highest sensitivity being set (potentiometer P1 turned 
all the way to the right and switch S2 set to position 2) when there is material between transmitter and 
receiver, there is a possibility that, due to

 

the position of the installation locations in relation to each other

 

the position of transmitter in relation to receiver or

 

too great a distance between transmitter and receiver,

the maximum detection range is limited.

7.  Notice

 

Avoid reflections on metal parts. 

8.  Declaration of Conformity

The described product meets the requirements of the following European directives:

Number:  89/336/EEC
Text: 

Electromagnetic compatibility

The accordance of the described product with the regulations of Directive No. 89/336/EEC is 
demonstrated by the complete compliance with the following standards:

Reference number 

Issue date 

Reference number 

Issue date

DIN EN 55011 

2007 

DIN EN 61000-4-3 

1997

DIN EN 61000-1 

 

DIN EN 61000-6-1 

2002

DIN EN 61000-3-2 

2001 

DIN EN 61000-6-2 

2000

DIN EN 61000-3-3 

2001 

DIN EN 61000-6-3 

2002

Содержание ProGap S

Страница 1: ...SWR engineering Messtechnik GmbH ProGap S Microwave barrier Betriebsanleitung EN Operating Instructions...

Страница 2: ...2 CONTENTS Page 1 General 3 2 Mounting and Installation 3 3 Electrical Connection 4 3 1 Safety Instructions 5 4 Safety 7 5 Commissioning 8 6 Trouble Shooting 9 7 Notice 9 8 Declaration of Conformity...

Страница 3: ...ures up to 20 bar as well as all DustEx zones the ProGap S can be used with the help of a process adapter 2 Mounting and Installation The device can be installed at any installation height However it...

Страница 4: ...on the metallic wall on the opposite side of the bin can be used for the reflection of the microwave The arrangement of transmitter and receiver mustn t be exactly parallel to each other in this insta...

Страница 5: ...oup Equipment category For explosive mixtures of air and combustible dusts Degree of protection Maximum surface temperature at maximum ambient temperature Ta 60 C 3 1 Safety Instructions Hazardous Are...

Страница 6: ...safety instructions in the operating instructions 2 Install the device according to the manufacture s instructions and any other valid standards and regulations 3 The device may not be operated outsid...

Страница 7: ...microwave barrier must be installed by trained and authorised personnel only In case of maintenance work on the pipe or on components of the ProGap S sensor make sure that the piping is in unpressuri...

Страница 8: ...only rotate P1 counter clockwise until LED 1 is turned off Repeat the process If LED 1 continues to glow even if P1 is turned all the way to the left and if the materials are materials with a low die...

Страница 9: ...ransmitter and receiver the maximum detection range is limited 7 Notice Avoid reflections on metal parts 8 Declaration of Conformity The described product meets the requirements of the following Europ...

Страница 10: ...ng power max 5 mW Weight Transmitter approx 560 g Receiver approx 560 g SWR engineering Messtechnik GmbH Gutedelstra e 31 79418 Schliengen Germany Fon 49 7635 82 72 48 0 Fax 49 7635 82 72 48 48 www sw...