background image

Operating Instructions

7

4.  Safety

The ProGap S was designed, built and tested to be safe and was shipped in safe condition.  
Nevertheless persons or objects may be endangered by components of the system if these are operated in an 
inexpert manner. Therefore the operational instructions must be read completely and the safety notes must be 
followed.
In case of inexpert or irregular use, the manufacturer will refuse any liability or guarantee.

4.1  Regular Use

 

Only original spare parts and accessories of SWR engineering must be used. 
 

4.2  Identification of Dangers

 

Possible dangers when using the sensor are marked in the operating instructions.

4.3  Operational Safety

 

The microwave barrier must be installed by trained and authorised personnel only.

 

In case of maintenance-work on the pipe or on components of the ProGap S-sensor, make sure that the 
piping is in unpressurized condition.

 

Switch off the power supply for all maintenance, cleaning or inspection works on the tubes or on 
components of the ProGap S. 

 

Before hot work the microwave barrier must be removed from the installation place.

 

The components and electrical connections must be checked for damages regularly. If a damage is 
found, it is to be repaired before further operation of the instruments. 

 

4.4   Technical Progress

 

The manufacturer reserves the right to adapt technical data to the technical progress without particular 
advance notice. If you have any questions, SWR engineering will be pleased to inform you on possible 
changes and extensions of the operating instructions.

Содержание ProGap S

Страница 1: ...SWR engineering Messtechnik GmbH ProGap S Microwave barrier Betriebsanleitung EN Operating Instructions...

Страница 2: ...2 CONTENTS Page 1 General 3 2 Mounting and Installation 3 3 Electrical Connection 4 3 1 Safety Instructions 5 4 Safety 7 5 Commissioning 8 6 Trouble Shooting 9 7 Notice 9 8 Declaration of Conformity...

Страница 3: ...ures up to 20 bar as well as all DustEx zones the ProGap S can be used with the help of a process adapter 2 Mounting and Installation The device can be installed at any installation height However it...

Страница 4: ...on the metallic wall on the opposite side of the bin can be used for the reflection of the microwave The arrangement of transmitter and receiver mustn t be exactly parallel to each other in this insta...

Страница 5: ...oup Equipment category For explosive mixtures of air and combustible dusts Degree of protection Maximum surface temperature at maximum ambient temperature Ta 60 C 3 1 Safety Instructions Hazardous Are...

Страница 6: ...safety instructions in the operating instructions 2 Install the device according to the manufacture s instructions and any other valid standards and regulations 3 The device may not be operated outsid...

Страница 7: ...microwave barrier must be installed by trained and authorised personnel only In case of maintenance work on the pipe or on components of the ProGap S sensor make sure that the piping is in unpressuri...

Страница 8: ...only rotate P1 counter clockwise until LED 1 is turned off Repeat the process If LED 1 continues to glow even if P1 is turned all the way to the left and if the materials are materials with a low die...

Страница 9: ...ransmitter and receiver the maximum detection range is limited 7 Notice Avoid reflections on metal parts 8 Declaration of Conformity The described product meets the requirements of the following Europ...

Страница 10: ...ng power max 5 mW Weight Transmitter approx 560 g Receiver approx 560 g SWR engineering Messtechnik GmbH Gutedelstra e 31 79418 Schliengen Germany Fon 49 7635 82 72 48 0 Fax 49 7635 82 72 48 48 www sw...