background image

Operating Instructions

8

5.  Commissioning

All operating controls required for calibration can be 
found in the receiver.

P1: 

Setting the threshold level 

   

through sensitivity.

P2: 

Setting the delay of the switch-off signal.

S1: 

Relay active / passive

S2: 

Doubling the sensitivity

LED 1: 

shows the switching status of the relay.

 

LED on = relay is closed

LED 2: 

shows the signal strength through flashing.

 

fast flashing   = high signal strength

 

slow flashing  = low signal strength 

 

LED off           = no reception signal

Set shift pattern with potentiometer P1

The threshold level at which the relay is to be switched is set with potentiometer P1.
The microwave barrier  is set so that there are definite differentiations between an interrupted and  
a muted / non-interrupted microwave beam.

Procedure

: In case of a non-interrupted beam and 

flashing LED 2

, rotate P1 clockwise until the relay 

switches and LED 1 glows at the same time. Now interrupt the beam (place material to be detected between 
transmitter and receiver) and only rotate P1 counter-clockwise until LED 1 is turned off. Repeat the process.  
If LED 1 continues to glow even if P1 is turned all the way to the left, and if the materials are materials with  
a low dielectric coefficient and weak attenuation (e. g. paper, plastic, foams), then please contact  
SWR engineering Messtechnik GmbH.

If LED 2 doesn’t flash, then set switch S2 to position 2, so that the sensitivity is doubled. If the LED itself 
does not flash even in this sensitive position, then the receiver is not receiving a signal from the transmitter. 
In this case, please check the microwave barrier for functionality with regard to the following:

 

Wrong alignment between the barriers

 

Distance between receiver and transmitter too great

 

Too much attenuating material in the beam

 

Attenuating crust built up on the sensors

Set switch delay time with potentiometer P2

Finally, set the switch-on /switch-off time with potentiometer P2 according to its requirements in a 
range from 0.25 to 5 seconds. A counter-clockwise rotation increases the delay. This can prevent a 
flutter in the switch relay caused by a critical sensitivity setting.

Fig. 8: Position of operating controls

LED 2

S1

S2

LED 1

P1
P2

Содержание ProGap S

Страница 1: ...SWR engineering Messtechnik GmbH ProGap S Microwave barrier Betriebsanleitung EN Operating Instructions...

Страница 2: ...2 CONTENTS Page 1 General 3 2 Mounting and Installation 3 3 Electrical Connection 4 3 1 Safety Instructions 5 4 Safety 7 5 Commissioning 8 6 Trouble Shooting 9 7 Notice 9 8 Declaration of Conformity...

Страница 3: ...ures up to 20 bar as well as all DustEx zones the ProGap S can be used with the help of a process adapter 2 Mounting and Installation The device can be installed at any installation height However it...

Страница 4: ...on the metallic wall on the opposite side of the bin can be used for the reflection of the microwave The arrangement of transmitter and receiver mustn t be exactly parallel to each other in this insta...

Страница 5: ...oup Equipment category For explosive mixtures of air and combustible dusts Degree of protection Maximum surface temperature at maximum ambient temperature Ta 60 C 3 1 Safety Instructions Hazardous Are...

Страница 6: ...safety instructions in the operating instructions 2 Install the device according to the manufacture s instructions and any other valid standards and regulations 3 The device may not be operated outsid...

Страница 7: ...microwave barrier must be installed by trained and authorised personnel only In case of maintenance work on the pipe or on components of the ProGap S sensor make sure that the piping is in unpressuri...

Страница 8: ...only rotate P1 counter clockwise until LED 1 is turned off Repeat the process If LED 1 continues to glow even if P1 is turned all the way to the left and if the materials are materials with a low die...

Страница 9: ...ransmitter and receiver the maximum detection range is limited 7 Notice Avoid reflections on metal parts 8 Declaration of Conformity The described product meets the requirements of the following Europ...

Страница 10: ...ng power max 5 mW Weight Transmitter approx 560 g Receiver approx 560 g SWR engineering Messtechnik GmbH Gutedelstra e 31 79418 Schliengen Germany Fon 49 7635 82 72 48 0 Fax 49 7635 82 72 48 48 www sw...

Отзывы: