10
Sensor
Material
Housing: Stainless steel 1.4571
Sensor-isolation: POM
Protective system
IP 65
Using in EX-Zones
As ProGap S Ex-sensor in DustEx-zone 20/22
and GasEx-zone 0/2 only with process-adapter
Process temperature
-20 … + 80 °C
-20 … +220 °C (with process-adapter)
max. 1000 °C (with ceramic flange)
Ambient temperature
-20 … +60 °C
Working pressure
max. 1 bar
max. 20 bar (with process-adapter)
Detection range
0 … 4 m
0 … 18 m
> 18 m (on demand)
Power supply
12 V DC powered by DIN Rail electronic
Power consumption
approx. 1.8 VA
Current consumption
max. 100 mA
Measuring frequency
K-Band 24.125 GHz (± 100 MHz)
Transmitting power
max. 5 mW
Weight
Transmitter: approx. 560 g
Receiver: approx. 560 g
SWR engineering Messtechnik GmbH
Gutedelstraße 31 · 79418 Schliengen (Germany)
Fon +49 7635 82 72 48-0 · Fax +49 7635 82 72 48-48 · www.swr-engineering.com
9. Technical Data
DIN Rail electronic
Power supply
24 V DC ± 10 %
Power consumption
3.5 W
Current consumption
120 mA at 24 V
Relay (max.)
• Voltage
• Current
• Capacity
250 V AC
1 A
60 W
Fall-delay time
0.25 … 5 s (continuously adjustable)
Weight
approx. 172 g
Protective system
IP 40
Mounting with separating flange
Mounting with pipe clamp
Thread mounting
A
B
Mounting types
The ProGap S can be easily installed in the following
ways:
•
Screwing it into a G 1½-inch threaded connection,
•
using a DN 40 flange or
•
using a pipe clamp or other holding bracket.
(All rights reserved.)
EN 24/11/2015
certificated
according to
ATE X