Remote Control Operation 

 
Description 
 
The following describes the operation of the remote control.  Some of these operations are only 
available on certain radios.  Refer to the Universal Remote Commands tables, or the Commands 
Quick Reference guides for specific features. 
 
Once you begin to use the remote you will get very comfortable with the operation.  There is a lot 
of functionality achieved by just a few remote buttons.  You can stick with the basic operations of 
the remote (frequency, and memory) and still achieve a lot of control over your radio.    The 
biggest problem you will have in the operation of the remote is the 

Enter

 key.  If you do not enter 

the codes exactly you will end up trying to enter a direct frequency.  Direct frequency entry can 
occur in either VFO or memory modes. 
 
Power 
 
Most Transceivers do not have the CI-V command implemented for power on and off, so the 
SWL IR Remote will not be able to power the Transceiver. 
 
Direct Frequency Entry 
 
When entering frequencies directly, be sure to press a digit key before the first decimal point.  
The 

Mute

 button functions to mute the radio, as a decimal point when entering frequencies, and 

as a clear to abort any key entry to that point.  When using the 

Mute

 button as a clear, be sure to 

press it enough times to get the LED to blink twice, or for the volume to mute.  This is 
confirmation that the clear command has been accepted.  When entering frequencies directly, the 

Mute

 key will operate as a decimal point only after a digit key has been pressed before the first 

decimal point.  As an example, you can enter 

0 Mute 3 Enter

 for 300KHz.  Pressing the 

Mute

 a 

second time during direct frequency entry will then enter 100Hz values.  To enter 15.235.500 you 
would enter 

1 5 Mute 2 3 5 Mute 5 Enter.

  Zeroes are assumed when not entered.  You can enter 

15.235.500 by pressing 

1

 

5

 

2

 

3

 

5

 

Mute

 

5 Enter

.  You can enter the frequency without any 

decimal places, but you need to enter all the zeros so the frequency is not misunderstood.  To 
enter 15.235.500 without using the decimal key, enter 

1 5 2 3 5 5 0 0 Enter

 
The SWL IR Remote assumes that you are entering frequencies in kHz.  Any frequency in kHz 
can be entered directly.  9565kHz would be entered as 

9 5 6 5 Enter

.  The decimal place (

Mute

is not necessary in this case.  The decimal place is only needed to save zero entries or optionally 
when entering a frequency less than 1MHz.  When entering frequencies below 1MHz, press a 
leading zero before the frequency and then 

Enter.

   For example: 

0 7 0 0 Enter

 for 700kHz.  Or 

use the 

Mute

 key as a decimal place before or after the frequency entry.  For example: 

7

 

0

 

0

 

Mute

 

Enter

 for 700kHz or 

0

 

Mute

 

7

 

Enter

 for 700 kHz. 

 
After a frequency has been entered, you can then use the 

CH+/-

 to step the frequency in the VFO 

mode.  Frequency steps of 1Hz, 10Hz, 100Hz, 1kHz, 5kHz, 9kHz, 10kHz, 100kHz, and 1MHz 
can be used to adjust an entered frequency very quickly or step through stations with set 
frequency spacing.  The 1Hz step is not available on the Yaesu FRG-100 or the Drake R8/A/B.  
The frequency resolution on the Yaesu FRG-8800 is 10Hz (frequency changes by 25Hz).  The 
1Hz, 10Hz, and 100Hz steps are not available on the Lowe HF-225.  You can set User Defined 
Tuning Steps for tuning CW and SSB below 1kHz.  Press a numeric key corresponding to the 
frequency step desired (see commands below), and then the 

CH+/-

 and the step frequency will be 

Содержание remote control for ICOM

Страница 1: ...4 2005 by swl remotes com All rights reserved Operating Manual SWL IR Remote Control for ICOM For Firmware Version 1 43 Web Site http www swl remotes com Support email support swl remotes com May 30 2...

Страница 2: ...is positive There is a blocking diode in the circuit so reverse polarity will not harm the SWL IR Remote control unit Customers in Europe receive a DC cable that connects to the coax power jack on the...

Страница 3: ...nsceiver leave the SWL IR Remote powered at all times or remove from the CI V port if not powered The RS 232C connector will be disabled if the SWL IR Remote is plugged into the CI V port and not powe...

Страница 4: ...an example you can enter 0 Mute 3 Enter for 300KHz Pressing the Mute a second time during direct frequency entry will then enter 100Hz values To enter 15 235 500 you would enter 1 5 Mute 2 3 5 Mute 5...

Страница 5: ...ve broadcaster You can set a frequency directly enter another frequency and return to the original frequency You can then enter another frequency and return etc The last frequency entered is lost if p...

Страница 6: ...io is powered off with the Power key on the remote the current memory channel is put into semi permanent memory so it can be restored even after the remote control unit is powered off Mute Operation T...

Страница 7: ...nter 15230 5kHz 1 5 2 3 5 Enter 15235kHz 9 5 6 5 Enter 9565kHz 3 Mute 5 Enter 3500kHz Mute Mute Mute Clear key entry during numeric entry LED will blink twice Frequency and Memory Channel stepping VFO...

Страница 8: ...irect Enter Commands Directly Selects radio features 8 x Enter Modes 1 LSB 2 USB 3 AM 4 CW 5 RTTY 6 FM 9 x Enter Filter Selection 1 Wide 2 Normal 3 Narrow Memory management x x Last Select Memory Chan...

Страница 9: ...CI V 5A Radio Baud 9600 baud Frequency Pacing 30 Optional Modes Disabled 0 9 6 Enter Enable Disable Optional Mode Selections 0 Enter Disable FM and CW modes in selections Factory default 1 Enter Enabl...

Страница 10: ...will NAK all commands and the LED will indicate a communications error If this occurs on every function and the radio is powered on and not responding check the cable connection the CI V address and...

Страница 11: ...e controller permits control over the flow of traffic to and from the radio IR commands can be interjected into the time between the computer commands permitting operation by the computer and the Univ...

Страница 12: ...the operation needs to be completed Push Mute to cancel the operation or x x Enter to complete the operation See chart above on the configuration command parameters Some buttons on the control work an...

Страница 13: ...ies are changed in any fashion other than the Universal Remote the SWL IR Remote can lose track of the currently selected memory Use the SWL IR Remote to perform memory operations or select the memory...

Отзывы: