SWL remote control for ICOM Скачать руководство пользователя страница 10

 

10 

Copyright © 2003, 2004, 2005 by swl-remotes.com, 

All rights reserved. 

LED Operation 

 
The LED provides feedback on the mode and operation of the SWL IR Remote.  The LED blinks 
slowly whenever there is a communications error (such as NAK from ICOM radios) or the 
communications has timed out waiting for a response when a response is expected.  The most 
common reason that the LED blinks slowly is a command that is not understood by the ICOM 
radio, and the radio has returned a NAK.  The NAK means that the radio does not understand the 
command, or the command contains a parameter out of bounds.  This can also occur if the radio is 
powered off and you try to initiate commands. 
 
Communications Error 
 
The LED blinks continuously at a slow rate when the communication times out from the radio, or 
a command is NAK’d.  If the radio power is off and you try to initiate any command but power 
on, the radio will NAK all commands and the LED will indicate a communications error.  If this 
occurs on every function and the radio is powered on and not responding, check the cable 
connection, the CI-V address and baud rate setting on the radio.  Also verify that the SWL IR 
Remote is correctly configured for the CI-V address and baud rate for the radio.  If optional 
modules are not installed in the radio and you try to use those functions, the radio will NAK the 
message. This is normal when the optional modules are not installed and will not cause improper 
operation or hang up. 
 
Clear Input 
 
After the 

Mute

 is used to clear key entries the LED will blink twice. 

  
Confirmation of Command 
 
After a valid command has been issued and acknowledged the LED will blink once and go out.  
The LED will appear to be on continuously when the 

CH+/-

 is held in the frequency mode, 

because the commands repeat and the LED doesn’t always time out. 
 
Configuration Mode 
 
When you enter the parameter configuration mode, the LED will blink continuously at a fast rate 
until the configuration operation is completed or canceled. 

Содержание remote control for ICOM

Страница 1: ...4 2005 by swl remotes com All rights reserved Operating Manual SWL IR Remote Control for ICOM For Firmware Version 1 43 Web Site http www swl remotes com Support email support swl remotes com May 30 2...

Страница 2: ...is positive There is a blocking diode in the circuit so reverse polarity will not harm the SWL IR Remote control unit Customers in Europe receive a DC cable that connects to the coax power jack on the...

Страница 3: ...nsceiver leave the SWL IR Remote powered at all times or remove from the CI V port if not powered The RS 232C connector will be disabled if the SWL IR Remote is plugged into the CI V port and not powe...

Страница 4: ...an example you can enter 0 Mute 3 Enter for 300KHz Pressing the Mute a second time during direct frequency entry will then enter 100Hz values To enter 15 235 500 you would enter 1 5 Mute 2 3 5 Mute 5...

Страница 5: ...ve broadcaster You can set a frequency directly enter another frequency and return to the original frequency You can then enter another frequency and return etc The last frequency entered is lost if p...

Страница 6: ...io is powered off with the Power key on the remote the current memory channel is put into semi permanent memory so it can be restored even after the remote control unit is powered off Mute Operation T...

Страница 7: ...nter 15230 5kHz 1 5 2 3 5 Enter 15235kHz 9 5 6 5 Enter 9565kHz 3 Mute 5 Enter 3500kHz Mute Mute Mute Clear key entry during numeric entry LED will blink twice Frequency and Memory Channel stepping VFO...

Страница 8: ...irect Enter Commands Directly Selects radio features 8 x Enter Modes 1 LSB 2 USB 3 AM 4 CW 5 RTTY 6 FM 9 x Enter Filter Selection 1 Wide 2 Normal 3 Narrow Memory management x x Last Select Memory Chan...

Страница 9: ...CI V 5A Radio Baud 9600 baud Frequency Pacing 30 Optional Modes Disabled 0 9 6 Enter Enable Disable Optional Mode Selections 0 Enter Disable FM and CW modes in selections Factory default 1 Enter Enabl...

Страница 10: ...will NAK all commands and the LED will indicate a communications error If this occurs on every function and the radio is powered on and not responding check the cable connection the CI V address and...

Страница 11: ...e controller permits control over the flow of traffic to and from the radio IR commands can be interjected into the time between the computer commands permitting operation by the computer and the Univ...

Страница 12: ...the operation needs to be completed Push Mute to cancel the operation or x x Enter to complete the operation See chart above on the configuration command parameters Some buttons on the control work an...

Страница 13: ...ies are changed in any fashion other than the Universal Remote the SWL IR Remote can lose track of the currently selected memory Use the SWL IR Remote to perform memory operations or select the memory...

Отзывы: