background image

1. Connect the motor festo fitting to a section of 4mm tubing (included).
2. Route the tubing to the filter then to the shut off as shown.
3. Connect the other end of the shutoff with 4mm tubing to the output of the supertrap pump.
4. Plumb the UAT as shown and per the UAT instructions (UAT is not included)
5. Plumb the Fuel tank per the manufacturer instructions noting orientation above.
6. Connect Input of fuel pump to UAT fuel out fitting
7. Double check your fittings
8. Use 20 gauge stainless wire to secure tubing to non-festo connections

Startup Operation

Prior to running the turbine walk around the aircraft or motor stand and make sure that all power and data
connections are placed properly.

1. Turn the fuel valve to the on position
2. Turn on power to the receiver and observe GSU startup. The motor and GSU will sync up with an audible signal.
3. If this is the first startup, use the test menu and locate “test pump” function.
4. Prime the lines with fuel using the test pump function. The fuel line to the motor can be placed into a tank to

circulate fuel then connected to the motor when primed.

Failure to conduct this exercise will cause the motor not to run.

Note: Some users report running the pump for a few minutes with fuel circulating to “break in” the pump before

running the engine for the first time.

5. Turn on power to the Radio Controller. Note an audible sync signal when the radio is powered up. This lets the

user know that the motor is online with connection to the radio.

6. Raise the trim to 100% and observe ECU status “ready”
7. Raise the throttle stick to full then to min. This will initiate a start sequence.
8. The starter motor will begin to spin. The ECU will switch to ignition, then to preheat, then to ramp. As the motor

begins to ramp the pump begins to pump more and more aggressively. When the motor reaches idle speed the
ECU will train to the motor. For first time users, the ECU will switch first to “learn RC” then will indicate learn stick
high. Raise the throttle to full and allow the motor and ECU to train to full RPM. Please be sure to brace the aircraft
from moving now.

9. The ECU will now indicate learn Stick low.
10. Return the stick to low position. The motor will now switch to “running” and motor function is transferred to the

user.

Shutdown Procedure

Always observe proper shutdown and cooling of the turbine. Failure to observe proper shutdown by not properly

Содержание SW Brushless Series

Страница 1: ...SWIWIN Turbines SW Brushless Series Kero Start Full Autostart with Auto Restart Operations Manual ...

Страница 2: ...njury to the user or bystanders Our responsibility is explicitly limited to the motor and to the internal workings and ancillary supplies offered with the turbine SWIWIN USA advises ALL users novice or pro to test their motors in a test stand before mounting them in a plane The reason for this is to familiarize yourself with SWIWIN motor operation and to ensure reliable operation before mounting t...

Страница 3: ...r a fire extinguisher and it was not where it needed to be and or the extinguisher was not operational Failsafe Please read carefully the notes on setting the failsafe on your radio to of interference or loss of signal Ear Protection Turbines produce excessive dB levels of noise when running the engine Burns Exhaust gases are very hot up to 1000 C and can cause burns to skin or damage to objects c...

Страница 4: ...such repair or replacement is required and is due to a malfunction during normal usage 2 SWIWIN will cover labor charges associated with any warranty repair 3 SWIWIN warranty coverage is limited to replacement of parts and repair of the unit and does not apply to any other losses or damages consequential or inconsequential to the failure 4 Buyer is required to register the motor with SWIWIN at the...

Страница 5: ...one number email address etc Please also include a photo copy of the original sales receipt 8 Owner agrees to cover charges for all parts and or labor charges not covered by this warranty 9 In the event that a turbine is returned and it is later determined that the engine has failed due to issues that are not covered under the warranty see above conditions the owner will be provided with a repair ...

Страница 6: ...ry cable to ECU port labeled 3S LIPO BATT 3 Connect the pump to the deans connector on the battery cable 4 Connect the GSU to the ECU port labeled GSU PC 5 Connect the engine cable to the ECU port labeled ENGINE Engine cable Brushless pump and Traditional pump Throttle line Battery power cable Motor Setup Please refer to Figure 3 Motor Setup above ...

Страница 7: ...med Failure to conduct this exercise will cause the motor not to run Note Some users report running the pump for a few minutes with fuel circulating to break in the pump before running the engine for the first time 5 Turn on power to the Radio Controller Note an audible sync signal when the radio is powered up This lets the user know that the motor is online with connection to the radio 6 Raise th...

Страница 8: ...in continuously until the motor is cooled Previous firmware releases spun the motor intermittently to save the life of the motor 4 Turn off the fuel 5 Turn off power to the controller 6 Turn off power to your radio ECU The SWIWIN ECU was designed from the ground up and is based on 32 bit microprocessor functionality and designed specifically for SWIWIN Turbines The ECU offers the following benefit...

Страница 9: ...PM 0 100 Temp 0 1000 Celsius Pump output measured in volts ex 4500 1000 4 5 volts RC throttle position from 0 100 Large font Running Screen Press C to toggle between large screen and normal Main menu initial screen From the initial screen press OK key click C to toggle back to boot screen StartUp enter startup menu Running enter Running menu Adjust RC Train Radio to ECU Starter set starter power C...

Страница 10: ...g Display RPM Acceleration Deceleeation Curve Delay time Higher values mean a faster rpm increase decrease rate Adjust according to weather Altitude ASL or other conditions which require adjustments to delay time It is best to select a value that is lower than a setting that yields the fastest possible response time in order to avoid a flame out Raise value to decrease response time Lower value to...

Страница 11: ...try mode 1 1 for single engine mode Starter Eject Time sets the time for a reverse voltage pulse to disengage the starter Eject Voltage sets the eject voltage in order disengage the clutch on startup Run Voltage Sets the voltage for the starter during startup RPM Stable rpm adjust rate of starter Engine Cooling Sets the cooling rpm after shut down or when starter is manually run using test functio...

Страница 12: ...increase pump speed Pump increases gradually Test pump initiates fuel solenoids simultaneously Be careful not to flood the engine Test Fuel Valve press OK to activate fuel valve Test Gas Valve press OK to activate Gas Valve this controls fuel to the glow plug Test Glow Plug press OK to activate Glow Plug circuit A glow can be seen from the rear of the motor Test Starter Press OK to activate starte...

Страница 13: ...Spec ...

Страница 14: ... 144 000RPM 310g min 112 500RPM 325g min 115 200RPM 351g min 99 000RPM 380g min 10 3500RPM Fuel kero or diesel kero or diesel kero or diesel kero or diesel kero or diesel Lubrication 5 kero 3 diesel 5 kero 3 diesel 5 kero 3 diesel 5 kero 3 diesel 5 kero 3 diesel Maintenance Interval 25Hours 25Hours 25Hours 25Hours 25Hours Service www sw jet com Service sale sw jet qq com Name Thomas Chiang USA Ser...