Start Up Screen
PumpVoltage - Set pump voltage Typical value is 0.4-0.5v
RPM StartUp Ramp – Set ramp profile starter , This parameter
adjusts the speed of the starter increase during the “Preheat to RPM
Off Starter” phase. Higher values mean a faster rpm increase.
Increase this value if the engine too hot duing preheat to rpm off
starter , and decrease it if flame out duing preheat to rpm of starter.
Pump StartUp Ramp - This parameter adjusts the speed of the fuel
increase during the “Fuel ramp” phase. Higher values mean a faster
fuel flow increase. Increase this value if the engine takes too long to
arrive to idle, and decrease it if the starts are too hot, with the
engine overshooting the idle speed.
GlowPlug – Set Glow Plug Voltage.
GasValve – Set the values of time of the gas fuel valve is open at
beginning of the ignition phase.
Ignition RPM – Set the RPM where ignition phase commences
Preheat RPM – Set the RPM value for preheat phase to begin.
RPM Off Starter – Set the RPM where the starter motor will
disengage.
Running Display
RPM Acceleration/Deceleeation Curve/Delay time
Higher values mean a faster rpm increase/decrease rate. Adjust
according to weather, Altitude (ASL) or other conditions which
require adjustments to delay time. It is best to select a value that is
lower than a setting that yields the fastest possible response time in
order to avoid a flame out.
Raise value to decrease response time, Lower value to increase
response time
Max RPM – Set maximum RPM
Idle RPM – set idle RPM
Min RPM – set stop RPM , if motor RPM falls below this setting,
motor will shutdown.
MaxTemp - Set maximum running temp.If motor exceeds this value,
ECU will automatically limit fuel in order to reduce the temp.
LowVolt – set low volt warning
Restart - Can be set “valid” for enable or
“
invalid” disabled, flame
out automatically restart or not.
Restart power pump – set power to pump on restart. Normal range
from 0.3 – 0.7 Volt
PumpLimit – This value is used to set the limit to the pump to a
reasonable limit and is based on observation of actual running
values. Set this value to 20% higher than what is observed on the
main screen. This prevents excess pump pressure.
IdlePumpStab – set pump stable delay on idle rpm, normaly SW60B
tubine set 5-8, SW120-210 set 3-5