background image

User acknowledges the risk of injury or burns to bystanders during start-up or
while operating a turbine. User agrees to take all steps necessary to ensure that
all persons are situated a safe distance from the operations of the engine.

Please refer to figure 1. Always ensure, that all bystanders maintain a safe
distance from the engine.
clear of the area to the
rarely catastrophically malfunction but in the rare event of an issue, it is best to
maintain a safe distance.

Fire extinguishers – It is absolutely crucial to have at least one CO2 extinguisher
and a Class ABC extinguisher on hand at all times. CO2 is the only recommended
application for a motor fire. A dry chemical extinguisher will work to extinguish a
fire but the residue left behind from dry chemical extinguishers does heavy
damage to a running turbine. If a chemical extinguisher is used to douse a
running engine fire, the motor will need to be completely dissembled and
cleaned.

figure 1

Important Note: Please be sure to inspect all extinguishers each day that a turbine is being used. There are countless
recounts by pilots and assistants where they reached for a fire extinguisher and it was not where it needed to be
and/or the extinguisher was not operational.

Failsafe. Please read carefully the notes on setting the failsafe on your radio to of interference or loss of signal.

Ear Protection – Turbines produce excessive dB levels of noise. when running the engine.

Burns - Exhaust gases are very hot (up to 1000°C) and can cause burns to skin or damage to objects close to it – keep
exhausts clear of anything which is affected by such heat.

Turbine Oil Toxicity - Turbine oil is poisonous. Keep it away from the mouth and eyes andfrom contact with skin. Always
store it in out the role of fireman. Ensure that they are aware of what to do in event of emergency and where to
position the extinguishers.

Turbine Oil – Turbine oil is required for operation of your turbine. Use of any non-approved oil such as 2 cycle oil voids
the warranty.

SWIWIN Limited Lifetime Warranty

SWIWIN warrants each turbine to be free from defects in materials and workmanship during normal usage, according
to the following terms and conditions.

1. The warranty is transferable to any subsequent user. There is a $50 admin fee which will be collected when

ownership of the motor is transferred. Please make sure that each user registers the motor with SWIWIN at the
time of transfer so that service can be maintained on the motor.

Содержание SW Brushless Series

Страница 1: ...SWIWIN Turbines SW Brushless Series Kero Start Full Autostart with Auto Restart Operations Manual ...

Страница 2: ...njury to the user or bystanders Our responsibility is explicitly limited to the motor and to the internal workings and ancillary supplies offered with the turbine SWIWIN USA advises ALL users novice or pro to test their motors in a test stand before mounting them in a plane The reason for this is to familiarize yourself with SWIWIN motor operation and to ensure reliable operation before mounting t...

Страница 3: ...r a fire extinguisher and it was not where it needed to be and or the extinguisher was not operational Failsafe Please read carefully the notes on setting the failsafe on your radio to of interference or loss of signal Ear Protection Turbines produce excessive dB levels of noise when running the engine Burns Exhaust gases are very hot up to 1000 C and can cause burns to skin or damage to objects c...

Страница 4: ...such repair or replacement is required and is due to a malfunction during normal usage 2 SWIWIN will cover labor charges associated with any warranty repair 3 SWIWIN warranty coverage is limited to replacement of parts and repair of the unit and does not apply to any other losses or damages consequential or inconsequential to the failure 4 Buyer is required to register the motor with SWIWIN at the...

Страница 5: ...one number email address etc Please also include a photo copy of the original sales receipt 8 Owner agrees to cover charges for all parts and or labor charges not covered by this warranty 9 In the event that a turbine is returned and it is later determined that the engine has failed due to issues that are not covered under the warranty see above conditions the owner will be provided with a repair ...

Страница 6: ...ry cable to ECU port labeled 3S LIPO BATT 3 Connect the pump to the deans connector on the battery cable 4 Connect the GSU to the ECU port labeled GSU PC 5 Connect the engine cable to the ECU port labeled ENGINE Engine cable Brushless pump and Traditional pump Throttle line Battery power cable Motor Setup Please refer to Figure 3 Motor Setup above ...

Страница 7: ...med Failure to conduct this exercise will cause the motor not to run Note Some users report running the pump for a few minutes with fuel circulating to break in the pump before running the engine for the first time 5 Turn on power to the Radio Controller Note an audible sync signal when the radio is powered up This lets the user know that the motor is online with connection to the radio 6 Raise th...

Страница 8: ...in continuously until the motor is cooled Previous firmware releases spun the motor intermittently to save the life of the motor 4 Turn off the fuel 5 Turn off power to the controller 6 Turn off power to your radio ECU The SWIWIN ECU was designed from the ground up and is based on 32 bit microprocessor functionality and designed specifically for SWIWIN Turbines The ECU offers the following benefit...

Страница 9: ...PM 0 100 Temp 0 1000 Celsius Pump output measured in volts ex 4500 1000 4 5 volts RC throttle position from 0 100 Large font Running Screen Press C to toggle between large screen and normal Main menu initial screen From the initial screen press OK key click C to toggle back to boot screen StartUp enter startup menu Running enter Running menu Adjust RC Train Radio to ECU Starter set starter power C...

Страница 10: ...g Display RPM Acceleration Deceleeation Curve Delay time Higher values mean a faster rpm increase decrease rate Adjust according to weather Altitude ASL or other conditions which require adjustments to delay time It is best to select a value that is lower than a setting that yields the fastest possible response time in order to avoid a flame out Raise value to decrease response time Lower value to...

Страница 11: ...try mode 1 1 for single engine mode Starter Eject Time sets the time for a reverse voltage pulse to disengage the starter Eject Voltage sets the eject voltage in order disengage the clutch on startup Run Voltage Sets the voltage for the starter during startup RPM Stable rpm adjust rate of starter Engine Cooling Sets the cooling rpm after shut down or when starter is manually run using test functio...

Страница 12: ...increase pump speed Pump increases gradually Test pump initiates fuel solenoids simultaneously Be careful not to flood the engine Test Fuel Valve press OK to activate fuel valve Test Gas Valve press OK to activate Gas Valve this controls fuel to the glow plug Test Glow Plug press OK to activate Glow Plug circuit A glow can be seen from the rear of the motor Test Starter Press OK to activate starte...

Страница 13: ...Spec ...

Страница 14: ... 144 000RPM 310g min 112 500RPM 325g min 115 200RPM 351g min 99 000RPM 380g min 10 3500RPM Fuel kero or diesel kero or diesel kero or diesel kero or diesel kero or diesel Lubrication 5 kero 3 diesel 5 kero 3 diesel 5 kero 3 diesel 5 kero 3 diesel 5 kero 3 diesel Maintenance Interval 25Hours 25Hours 25Hours 25Hours 25Hours Service www sw jet com Service sale sw jet qq com Name Thomas Chiang USA Ser...

Отзывы: