![SWIT Electronics S-1073F Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/swit-electronics/s-1073f/s-1073f_user-manual_1415521013.webp)
13
Audio Bar, Histogram, False Color, AFD, H/V Delay, R/G/B/Mono, Marker, Color Bar, UMD, Audio
Alarm, Max backlight, Focus Assist, Aspect Ratio, Scan Mode, Zoom Mode, Mute, Freeze Frame, Flip
Mode, Waveform, Color Temp, Timecode, Zebra, Vector.
For example: Set F3 to “R/G/B/Mono” under “Function key” submenu. User can press F3 on the
front panel to adjust the parameters of “R/G/B/Mono”, and the “R/G/B/Mono” will change and follow the
sequence: Blue Only
→Red Only →Green Only →Mono →Off.
5. GPI
User can set GPI pins to relevant functions to turn on or off this function.
*1 When “GPI control” is set to “On”, the monitor can be operated through external GPI control unit.
*2 The GPI pins can be setted to the down below functions:
Red Tally, Green Tally, Yellow Tally, Aspect Ratio, Scan Mode, Zoom Mode, Mute, Freeze Frame,
Flip Mode, Color Temp, Time code, Zebra, Vector, Audio Bar, Histogram, False Color, AFD, H/V Delay,
R/G/B/Mono, Marker, Color Bar, UMD, Audio Alarm, Max backlight, Focus Assist.
When connecting the GPI pin with ground, the setted function will be turned on, and goes out
when disconnecting.
Example 1: Under “GPI ” submenu, set “GPI control” to “On”, set “2
Pin” to “Red Tally”, when the pin 2 of the extenal GPI control unit is
connected with ground, the Tally light will display on the front panel which
will flashes in red around every second. When disconnected, the monitor
will not display tally light information.
Example 2: Under “GPI ” submenu, set “GPI control” to “On”, set “4
Pin” to “Scan Mode”, when the pin 4 of the extenal GPI control unit is connected with ground, the Scan
mode will change and follow the sequence: “Normal” →”Overscan”→”Native” .