Page 23
This connector can be found on the left side of the filling machine
and is used by the signal cable for the turntable and mechanical
sensor (foot pedal, micro switch). If you are using a turntable and
a sesnor, connect it with the orange 3-pole connector from the
turntable.
1. +5 V
2. Start
3. 0 V, Earth
4. Stop
5. Ready signal for turntable
The Start/Stop signal must be “active low” They can beperated by
a contact or an NPN unit. The ready signal is an NPN active low-
signal.
Plug socket connections
5 pin socket mounted
on the left side of the
machine.
This connector is used for supplying an optional turntable
with power and can be found on the backside of the filling
machine.
1.
+24 V DC
2.
NC
3.
NC
4.
0 V, Ground
4-pin connector mounted on
the back of the machine.