background image

GB.FUNKRXHC.180907

We reserve the right to alter specifications.

6    www.swegon.com

SD

WLAN

CPU  1

CPU  2

1

A

2

B

3

GN D

4

+

5

-

6

+

7

-

8

+

9

-

10

+

11

-

12

+

13

-

SA  Temp

Com  5

Com  4

Com  3

Com  2

Com  1

14

+

15

-

16

+

17

-

18

+

19

-

Heat

Cool

20

C

21

NO

22

C

23

NO

24

C

25

NO

26

C

27

NO

28

P

29

G

30

G0

31

G

32

G0

24V AC

Sensor 1 Sensor 2

Sensor  4

Sensor 3

Com 6

Com 7

Com 8

Com 9

Com 10 Com 11

+

33

-

34

G

35

G0

36

Y

37

U

38

39 40

24V AC In

41 42

18V AC In

45 46

230V AC In

47

43 44

230V AC Ou t

-

97

+

98

GND

99

45

67

89

AB

CDEF

01

23

P1

COM POWER

IQlogic

+

1

2

3

4

5

6 7

8

9 10 11 12

-

+

-

+

-

+

+

-

-

S

-

S

C

13

NO

14

C

15

NO

16

+

17

-

18

+

19

-

20

G

21

G0

22

Com 1

Heat/Cool

Com 2

SD

WLAN

CPU  1

CPU  2

1

A

2

B

3

GN D

4

+

5

-

6

+

7

-

8

+

9

-

10

+

11

-

12

+

13

-

SA  Temp

Com  5

Com  4

Com  3

Com  2

Com  1

14

+

15

-

16

+

17

-

18

+

19

-

Heat

Cool

20

C

21

NO

22

C

23

NO

24

C

25

NO

26

C

27

NO

28

P

29

G

30

G0

31

G

32

G0

24V AC

Sensor 1 Sensor 2

Sensor  4

Sensor 3

Com 6

Com 7

Com 8

Com 9

Com 10 Com 11

+

33

-

34

G

35

G0

36

Y

37

U

38

39 40

24V AC In

41 42

18V AC In

45 46

230V AC In

47

43 44

230V AC Ou t

4. Wiring diagram 

The following wiring diagram deals with connected com-
ponents in addition to a standard air handling unit GOLD 
RX. For the wiring diagram standard GOLD RX, see the 
separate document.

Control card 
IQlogic

Control card iPro, 
cooling circuit 
control

Pressure sensor for pressure drop 
measurement over the cooling circuit’s 
exhaust air coil (function selector 
switch in D position).

Temperature sensor for density cor-
rection of the airflow. The sensor is 
placed between the coil and fan in the 
exhaust air/supply air.

 

Temperature sensor for density cor-
rection of the airflow. The sensor is 
placed between the coil and fan in the 
exhaust air/supply air.

 

Electric air heater for defrosting (accessory)

Connect from any of connectors COM1 or COM2 on the 
IQLogic

+

module to one of the connectors on the air han-

dling unit's IQLogic control unit marked COM6-11.

The function 
selector switch 
must be set to 
position 5.

Electric air 
heater

Control card 
IQlogic

IQlog-
ic+-module

Connect from connec-
tor HEAT/COOL on the 
IQlogic

+

-module to the 

RJ45 connector on the 
electric air heater.

Communication cable between connector COM4 on the air 
handling unit’s IQlogic control unit and communication termi-
nals 97, 98, 99 on the iPro cooling circuit control.

Communication cable between connector SENSOR4 
on the air handling unit’s IQlogic control unit and 
temperature sensor.

Communication cable between connector SENSOR3 
on the air handling unit’s IQlogic control unit and 
temperature sensor.

Communication cable between any connector 
COM6-11 on the air handling unit’s  
IQlogic control unit and pressure sensor.

Содержание RX/HC

Страница 1: ...ic air heater Option 3 Reversing the media circuit air recirculation section RX HC 1 1 Installation See the separate installation and maintenance instructions to install RX HC See the separate installation instructions to install the air recirculation section RX HC if used 2 Material specification Air handling unit with integrated reversible heat pump GOLD RX HC For defrosting according to option ...

Страница 2: ...rt sequence 3 3 Stop of RX HC air handling unit When stopping the GOLD air handling unit operation of the reversible heat pump is shut down immediately Post cooling of the refrigerant circuit and electric air heater for defrosting if fitted is carried out After cooling is in progress two minutes after the last operation of the compressor or electric air heater 3 4 Temperature regulation The heat p...

Страница 3: ... compressor is regulated to follow the tempera ture requirement At a temperature requirement below 62 5 the speed controlled compressor is run at 25 of max speed and the on off compressor is operational When the temperature requirement decreases below 50 the on off compressor shuts down and the speed controlled compressor is regulated to follow the tempera ture requirement At a temperature require...

Страница 4: ...ry heat exchanger is allowed to regulate to maintain the required supply air temperature If instead the temperature require ment exceeds MIN level operations return to normal mode If any of the following occurs the comfort function is can celled and operation of the reversible heat pump stops Stop of the GOLD air handing unit Time for comfort mode exceeds 30 minutes factory setting can be set 5 30...

Страница 5: ...esh air freezing occurs with varying speed and behaviour The pressure drop across the exhaust coil is measured to detect the defrosting requirement or stop ongoing defrosting Defrosting starts when the pressure drop exceeds a specific limit When the pressure drop falls below another lower limit defrosting stops At defrosting with recirculation the recirculation damper have a finishing sequence for...

Страница 6: ...ntrol card IQlogic Control card iPro cooling circuit control Pressure sensor for pressure drop measurement over the cooling circuit s exhaust air coil function selector switch in D position Temperature sensor for density cor rection of the airflow The sensor is placed between the coil and fan in the exhaust air supply air Temperature sensor for density cor rection of the airflow The sensor is plac...

Страница 7: ... P1 COM POWER IQlogic 1 2 3 4 5 6 7 8 9 10 11 12 S S C 13 NO 14 C 15 NO 16 17 18 19 20 G 21 G0 22 Com 1 Heat Cool Com 2 28 30 G G0 Y U G G0 31 32 P G0 G G0 1 2 1 2 1 2 8 9 G G0 Communication cable to the control unit of the air handling unit where it is connected to one of the outlets for COM 6 11 The function selector switch must be set to position 5 Outdoor air damper Exhaust air damper Air reci...

Страница 8: ...activated by selecting the required accessory from the menu HC defrosting accessory Set the required heating and cooling function standard or comfort Set the required values for outdoor temperature limits for heating and cooling Set the required values for airflow limits for supply air and extract air Calibration is carried out at the factory If recalibration is required this can be carried out by...

Отзывы: